Open Circuit Voltage Measurement (PV Terminals) |
Display Range
|
0.0VDC - 1000VDC
|
Measuring Range
|
5.0VDC - 1000VDC
|
Resolution
|
0.1VDC maximum
|
Accuracy
|
± (0.5 % + 2 digits)
|
Enunciators
|
DC voltage polarity correct or reversed
|
Short Circuit Current Measurement (PV Terminals)
|
Display Range
|
0.00ADC - 15.00ADC
|
Measuring Range
|
0.50ADC - 15.00ADC
|
Maximum Power
|
10kW
|
Resolution
|
0.01ADC maximum
|
Accuracy
|
± (1% + 2 digits)
|
Earth Continuity Resistance Measurement (4mm Terminals)
|
Test Voltage Open Circuit
|
>4VDC, nominal
|
Test Current into 2 Ω
|
>200mA
|
Display Range
|
0.00Ω - 199Ω
|
Measuring Range (EN 61557-4)
|
0.05Ω - 199Ω
|
Resolution
|
0.01Ω maximum
|
Accuracy
|
± (2% + 5 digits)
|
Test Leads Zero
|
Zero up to 10Ω, by zero button
|
Visible Warning
|
≥30V AC or DC at inputs
|
Circuitry Protection
|
Test inhibited if ≥30V AC or DC at inputs
|
Repeat tests as per IEC61557-4
|
Approx 4000 1 second test
|
Insulation Resistance (Auto Test Sequence, PV Terminals and Red 4mm Terminal)
|
Test Voltage Open Circuit
|
250V, 500V, 1000V (as per IEC61557-2)
|
Test Voltage Specification
|
-0% +20% (open circuit)
|
Test Voltage @ 1mA
|
>1mA into UN x (1000Ω/V)
|
Test Current Short Circuit
|
<2mA
|
Display Range
|
0.05MΩ - 200MΩ
|
Measuring Range (EN 61557-2)
|
0.05MΩ - 200MΩ
|
Resolution
|
0.01MΩ maximum
|
Accuracy
|
0.05MΩ - 100MΩ ± (5% + 5 digits)
|
|
101MΩ - 200MΩ ± (10% + 5 digits)
|
Visible Warning
|
≥ 30V AC or DC at inputs
|
Circuitry Protection
|
Test inhibited if ≥ 30V AC or DC at inputs
|
Repeat tests as per IEC61557-4
|
Approx 4000 1 second tests
|
Insulation Resistance (Point to Point, 4mm Terminals)
|
Test Voltage Open Circuit
|
250V, 500V, 1000V (as per IEC61557-2)
|
Test Voltage Specification
|
-0% +20% (open circuit)
|
Test Voltage @ 1mA
|
>1mA into UN x (1000Ω/V)
|
Test Current Short Circuit
|
<2mA
|
Display Range
|
0.05MΩ - 300MΩ
|
Measuring Range (EN 61557-2)
|
0.05MΩ - 300MΩ
|
Resolution
|
0.01MΩ maximum
|
Accuracy
|
± (5% + 5 digits)
|
Visible Warning
|
≥30V AC or DC at inputs
|
Circuitry Protection
|
Test inhibited if ≥ 30V AC or DC at inputs
|
Repeat tests as per IEC61557-4
|
Approx 4000 1 second tests
|
Rpe Voltage Measurement (4mm Terminals)
|
Display Range
|
30V - 440VAC/DC
|
Voltage Measuring Range
|
30V - 440VDC
|
|
30V - 440VAC 50-60Hz
|
Resolution
|
1V
|
Accuracy
|
± (5% + 2 digits)
|
Operating Current (via AC/DC Current Clamp)
|
Display Range
|
0.1A - 40.0A
|
Current Measuring Range
|
0.1A - 40.0A DC
|
|
0.1A - 40.0A AC 50-60Hz
|
Resolution
|
0.1A
|
Accuracy
|
± (5% + 2 digits)
|
DC Operating Power (via AC/DC Current Clamp and PV Terminals)
|
Display Range
|
0.00kW - 40kW
|
Measuring Range
|
0.50kW - 40kW
|
Resolution
|
0.01kW
|
Accuracy
|
± (5% + 5 digits)
|
General Specification:
|
Instrument Dimensions and Weight
|
Weight
|
1.04kg
|
Dimensions
|
26.4 x 10.7 x 5.8cm
|
Display
|
Custom LCD with backlight
|
Power Source
|
6 x 1.5V AA cells
|
Battery life
|
>1000 test sequences
|
Auto power down
|
User-programmable
|
Onboard memory
|
Up to 999 complete test datasets
|
Connectivity
|
USB download to PC (CSV format)
|
|
USB download to PC (CSV format)
|
|
NFC transfer of data to PVMobile Android App
|
|
iOS device not supported
|
App compatibility
|
Compatible with Android version 4.2 Jelly Bean
|
|
iOS devices not supported
|
Software compatibility
|
Compatible with SolarCert software (English language only)
|
Service
|