{{image.AltTag}} {{image.AltTag}}
Default Image Default Image

{{details.product.ModelName}}

Sku: {{details.product.ModelNumber}}

The INCON® Distribution Transformer Monitor (DTM) provides continuous, meter-grade precision performance monitoring of high-value, mission-critical, low-voltage pad mount and conventional pole mount transformers.
Please select an item in the list...
{{details.product.PriceUnits}}
Please fill out this field...
Please enter a number...
Please enter at least 1...
Please enter at max 999999...

You purchased this item on {{details.product.OrderHistory[0].OrderDate | date : 'yyyy-MM-dd'}}

Personal Greeting

DATA-DRIVEN DECISION MAKING

With the ability to monitor and trend transformer output voltage, loading (current) by phase, temperature, and Power Factor for an entire network of transformers, utilities are armed with powerful information regarding power distribution and equipment maintenance.

DTM - Notifications -Wide.psd

CUSTOMIZED ALARMS & NOTIFICATIONS

Via the CONVERGE™ web interface, utilities can be managed by exception with customized threshold alarms and notifications:

  • Voltage Signal Delta
  • Current Signal Delta
  • Fault Current
  • Voltage Sag and Swell
  • K-Factor Harmonics
  • Top/Bottom Tank Temperature
  • Temperature Delta
  • Winding Hot Spot Load Ratio
  • Winding Load
  • Winding Hot Spot Temperature
DTM - Install - Wide.psd

TRANSFORMER LIFE PREDICTION

By continuously monitoring the key indicators of a transformer’s performance, including temperature and load, the DTM not only tracks the loss of life in a transformer but also employs advanced predictive algorithms to forecast the estimated remaining run time.

CONTINUOUS MONITORING
The DTM continuously assesses transformer loading and thermal conditions to calculate the accumulated loss of life in real-time, updating at approximately two-second intervals.

ACCELERATION FACTOR
After each interval, the DTM updates the accumulated loss of life. This considers the exact interval duration and adjusts with an acceleration factor based on the loading and thermal conditions.

LIFETIME ESTIMATE
The average acceleration factor is then applied to any unmonitored time before the DTM was installed. This provides a thorough estimate of the total loss of life and can be used in predictive maintenance planning.

DTM-UNITE-Devices-Wide.psd

UNITE™ ASSET MANAGEMENT DATABASE

A secure MQTT communication protocol allows the DTM to communicate with the web-based UNITE™ asset management database safely. UNITE™ provides user-friendly access to all distribution transformer performance data for convenient centralized analysis and reporting.

ASSET MANAGEMENT
UNITE™ is a sophisticated IoT database with advanced data visualization tools for Franklin Electric monitoring systems like the DTM.

ANALYSIS
UNITE™ provides user-friendly access to voltage, temperature, current Power Factor data, and more for convenient analysis and reporting. 

CONSOLIDATION
Arm service and maintenance personnel with a consolidated view of an entire network of distribution transformer health and performance data.

DTM - Install Components - Wide.psd

EASY INSTALLATION

The DTM can be applied to any distribution transformer with a secondary output of 480 volts or less, phase to neutral. This includes single-phase, split-phase, or three-phase transformers. Installation has been kept simple, with only a few connections required to the transformer secondary.

SIMPLE CONNECTIONS

Four split-core Rogowski Coils measure load current. Five voltage leads measure Phase A, Phase B, Phase C, and neutral and ground. Two magnetically mounted RTD sensors measure the top and bottom transformer temperatures.

MAGNETIC MOUNTING

Four powerful 25 lbs. magnets integrated into the mounting plate allow the DTM to be installed vertically or horizontally without any drilling or adhesives. 

SETUP & CONFIGURATION

All user interface communication, including configuration of alarms and settings, data viewing, and alarm resetting, is made via the CONVERGE™ web interface. Configuration can be done locally via Wi-Fi using a web browser or remotely through the cellular connection.

 

 

 

TRANSFORMER STATE-OF-HEALTH

By continuously monitoring the key indicators of a transformer’s performance, including temperature and load, the DTM provides remote access to real-time transformer health data and automated threshold alarms for condition-based maintenance planning.

DTM-Icon-Transformer.psd

 

TRANSFORMER STATE-OF-HEALTH

By continuously monitoring the key indicators of a transformer’s performance, including temperature and load, the DTM provides remote access to real-time transformer health data and automated threshold alarms for condition-based maintenance planning.

DTM-Icon-Life.psd

TRANSFORMER LIFE PREDICTION

The DTM not only tracks the loss of life in a transformer but also employs advanced predictive algorithms to forecast the estimated remaining run time. The DTM ensures a near-constant assessment of the transformer’s health, considering real-time conditions and applying a calculated dynamic acceleration factor to predict the cumulative loss of life accurately.

DTM - Icon - Power Factor.psd

POWER FACTOR MONITORING

The DTM provides a transformer’s Power Factor, which is a trend of useful power delivered. Power Factor helps utilities to determine the most efficient distribution of power during peak times and to ensure the delivery of high-quality outbound power when their customers need it the most.

DTM - Icon - Hardware.psd

HIGH PERFORMANCE HARDWARE

A powerful industrial IOT grade processor and sophisticated polyphase energy measurement integrated circuit provide superior on-board computation capability and Power Quality Monitor level fidelity.

DTM-Icon-Anywhere.psd

DEPLOY ANYWHERE AT SCALE

A built-in Cat M1/NB2 cellular modem allows the DTM to communicate via a cellular network, enabling utilities to deploy DTMs virtually anywhere and at scale (i.e. one unit to thousands of units).

 

 

Components & Dimensions

DTM - Components - Wide.psd

1. IP68 weather-proof enclosure

2. Voltage leads (5)

3. Split-core Rogowski coils (4)

4. RTD temperature sensors (2)

5. Cable strain relief

6. Status indicator LED

7. Ethernet port (optional)

Transformer Monitor

Applications

  • 3-Phase Wye, 100-480V Line-Neutral, 50/60 Hz
  • 3-Phase (3 and 4-wire) Delta, 480V Line-Line, 50/60 Hz
  • 3-Phase Corner-Grounded Delta, 100-480V Line-Line, 50/60 Hz

Distribution Transformer Monitoring Reporting

  • Voltage ±10%, Frequency ±5%

Power Source

  • Powered from the transformer secondary via Phase A
    and N voltage leads

Temperature Sensors

  • 2 each RTDs, 25lb. Magnetic-mounted, 5-foot lead length

Current Sensors

  • 4 each, Rogowski Coils, 5-foot lead length

Fuses

  • Internal fuses on phase A and neutral leads (2 Amps)
Environmental

Enclosure Rating

  • NEMA 4X
  • IP65 (Ethernet Option)
  • IP66/67 (Cellular Option)

Operating Temperature/Humidity: -40°C to +60°C / 0 – 90% RH

Storage Temperature/Humidity Range: -40°C to +85°C / 0 – 95% RH

Communications

Local Communication: Wi-Fi (TCP/IP)

User Interface: Embedded web server running on Linux platform accessible via standard web browser

Protocols: MQTT

Embedded Device Options: Cat M1 Cellular

LED Indicator: Tri-color LED to indicate running and alarm states (can be deactivated)

Mechanical

Size (W x L x H): 6.25" x 7.75" x 3.75"

Weight: 5.5 Lbs.

Mounting: Magnet-mount is provided; pole-mount kit is available.

Standards IEC 61010 CAT IV 480V
Measured Parameters
Signal Channels Range Accuracy
Temperature 2 -50°C to +150°C ±3°C (1.5%)
10/12 Cycle RMS Voltage 3 90-480V RMS Lineto-
neutral
±0.5%
10/12 Cycle RMS Current 3 + Neut. 0-3000 Amps ±1%
Phase Angle 3 0° – 360° phase
difference
±2°
Line Frequency 3 47-63 Hz ±0.1 Hz
Power Factor 3 ± 1.000 ±0.05
Voltage THD 3 0% – 400% THD ±5% absolute
Current THD 3 0% – 400% THD ±5% absolute
Communication All User Interface communication including configuration of alarms and settings, data viewing and alarm resetting can be done locally via Wi-Fi using a web browser or remotely via the cellular connection.
           

 

 

 

 

Model Description
DTM-4-VZ Distribution Transformer Monitor with Verizon® Sim Card
DTM-4-ETH Distribution Transformer Monitor with Ethernet
UNITE-1 UNITE™ 3-month subscription equaling one unit (1 device, up to 10 users)

Included Hardware

  • Voltage leads (5)
  • Split-core Rogowski coils (4)
  • RTD temperature sensors (2)
  • Magnet mount