Comtest

8640B Series

Sku: BIR-8640B-Series

25kW, Forced-Air Cooled Moduload, RF Terminations

Product Information

8640B Series, RF Loads are compact high-power 50-ohm loads that efficiently dissipate up to 25 kW of RF over a wide frequency range up to 1 GHz.

    • Interlock control circuit provides fail-safe protection of the transmitter and load resistor in the event of an ac power failure to the blower or coolant pump.
    • Compact, low-profile design saves space in crowded transmitter sites.
    • Available Voltage Options (add suffix to model number).
      • 115V @ 60 Hz (-115)
      • 230V @ 50 Hz (-230)
      • 230V @ 60 Hz (-230-6)

    product specifications:

    Item No

    8640B Series

    Item Name

    25 kW, Forced-Air Cooled Terminations

    Power Rating

    25 kW continuous
    ** See note 2 above

    Frequency Range and VSWR

    1.1 max. 1 kHz – 900 MHz (DC for continuity checks)

    Temperture Range

    Water Only: +5 to +45 °C (41 to 113 °F)
    35% Ethylene Glycol: -20 to +35 °C (-4 to +95 °F)
    ** See note 2 above

    Coolant

    Cooling Method: Water dielectric and forced air convection
    Coolant: Distilled water or distilled water/ethylene glycol mixture
    Coolant Capacity: 9 qts. (8.5 L) nominal
    * See note 1 above

    Product Type

    Forced-Air Cooled

    Operating Position

    Horizontal Only

    Connectors

    See Model Matrix

    Finish

    Gray Powder Coat

    Dimensions

    26" x 19-5/8" x 19-1/4" (L x W x H)
    670 x 500 x 490 mm

    Weight

    155 lbs. (70 kg)

    Power

    115 V models: 11 A nominal @ 115V ± 10% 60Hz
    230 V models: 5-1/2 A nominal @ 230V ± 10% 50Hz

    Notes:

    • * Below 5°C, ONLY use 35% E.G. and 65% Dist. H2O mixture.
    • ** Above 30°C (86 °F) with water only, or 25°C (77 °F) with a 35% ethylene glycol mixture, derate power to 20 kW max.

    Model Selections

    Model Connector
    8645B 3-1/8" EIA, Flanged
    8646B 3-1/8" EIA, Unflanged