Fluke 115 Field Technicians Digital Multimeter
Sku: FLK-115
Price: R8268,50 – R9890,00Price range: R8268,50 through R9890,00 incl Vat
Fluke 115 True-RMS Digital Multimeter
Product Information
Fluke 115 True-RMS Digital Multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.
The 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:
- AC and DC voltage to 600V,
- AC and DC current to 10 A (20 A overload for 30-seconds max).
- Compact True-rms digital multimeter for field service
- Includes: meter, holster, 4 mm PVC-Insulated test lead
- Easy one-handed operation of the meter
- Min/Max/Average to record signal fluctuations
| Specifications | ||
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| AC amps True RMS (45 Hz to 500Hz) |
Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.5% + 3 20 A overload for 30-seconds max |
|
| DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.0% + 3 20 A overload for 30-seconds max |
|
| Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50.00 kHz / 0.01 kHz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉. |
||
| General Specifications | |
| Maximum voltage between any terminal and earth ground | 600 V |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
| Display | Digital: 6,000 counts, updates 4 per second |
| Bar graph | 33 segments, updates 32 per second |
| Operating temperature | -10℃ to + 50℃ |
| Storage temperature | -40℃ to + 60℃ |
| Battery type | 9 volt Alkaline, IEC 6LR61 |
| Battery life | 400 hours typical, without backlight |
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
| Weight | 550 g |
| Warranty | 3 years |
FLUKE-115
Includes:
- Holster
- Installed 9V battery
- 4 mm PVC-Insulated test lead
- User manual
Compatible accessories: Fluke 115 Field Technicians Digital Multimeter
Cases and holsters
- Fluke C50 Meter Case
- Fluke CXT170 Extreme Case
- Fluke C25 Large Soft Case for DMMs
- Fluke C35 Soft Carrying Case
- Fluke C37XT Protective EVA Hard Tool Case
Test leads, probes and clips
- Fluke TL220 SureGrip™ Industrial Test Lead Set
- Fluke AC285 SureGrip™ Alligator Clips
- Fluke AC87 Heavy Duty Bus Bar Clip Set
- Fluke TL223 SureGrip™ Electrical Test Lead Set
- Fluke TL71 Premium Test Lead Set
- Fluke TL175 TwistGuard™ Test Leads
- Fluke TL75 Hard Point™ Test Lead Set
- Fluke TL224 SureGrip™ Insulated Test Leads
- Fluke TLK-220 SureGrip™ Industrial Test Lead Kit
- Fluke TLK-225 SureGrip Master Accessory Set
- Fluke TP220 SureGrip™ Industrial Test Probes
- Fluke TP1 Slim Reach Test Probes
- Fluke TL175-HV CAT III 1500 V TwistGuard™ Test Leads
Lights
- Fluke LVD1A Non-Contact Voltage Tester with LED Flashlight
- Fluke L206 Deluxe LED Hat Light
Probes
- Fluke 80PK-9 General Purpose Probe
- Fluke 80PK-27 SureGrip™ Industrial Surface Temperature Probe
Thermometer
- Fluke 80TK Thermocouple Module
Adapters and cables
- Fluke TL20 Industrial Test Lead Kit
Current clamps and probes
- Fluke i1010 AC/DC Current Clamp
For More Information, click here.
Manuals
- 114, 115, 117 | Users manual
- 114, 115, 117 | Users manual supplement
- 115C, 117C | Users manual
- 114, 115, 116, and 117 | Calibration information
- 114, 115, 116, and 117 | Calibration information supplement
- 117, 116,115,114,113 and 110 Plus | Statement of memory volatility
Data Sheets
- Add wireless to your Fluke digital multimeter
- Extended Specs For 114, 115, 116, 117
- Fluke 115 Multimeter Data Sheet
Selection Guide