Fluke 116 Digital HVAC Multimeter
Sku: FLK-116
Price: R8958,50 incl Vat
Fluke 116 Digital Multimeter
Product Information
Fluke 116 Digital HVAC Multimeter provides the features you need to quickly troubleshoot HVAC equipment
Fluke 116 Digital HVAC Multimeter was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.
Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.
- Digital multimeter designed specifically for HVAC professionals
- Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
- Provides microamps to test flame sensors
- Features low input impedance to helps prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas
Other useful features:
- Measures resistance, continuity, frequency, and capacitance
- Provides Min/Max/Average to record signal fluctuations
- Comes with a holster with probe holders for easy storage
- Features a compact ergonomic design for one-handed operation
- Fits into optional ToolPak™ magnetic hanger for hands-free operation
- CAT III 600 V safety rated
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to + 50°C | |
| Storage temperature | -40°C to + 60°C | |
| Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode Test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z Capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| Temperature² (Type-K thermocouple) |
Range/resolution | -40°C to 400°C / 0.1°C |
| Accuracy | 1% + 10² | |
| Range/resolution | -40°F to 752°F / 0.2°F | |
| Accuracy | 1% + 18² | |
| AC μA true-rms (45 Hz to 500 Hz) | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.5% + 3 | |
| DC μamps | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.0% + 2 | |
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
| Warranty | 3 years | |
Fluke 116
Includes:
- 4 mm silicone test lead set
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
- User manual
Compatible accessories: Best HVAC Multimeter – Fluke 116 Digital HVAC Multimeter
Cases and holsters
- Fluke C115 Soft Carrying Case
- Fluke C50 Meter Case
- Fluke CXT170 Extreme Case
- Fluke C25 Large Soft Case for DMMs
- Fluke C35 Soft Carrying Case
- Fluke C37XT Protective EVA Hard Tool Case
Test leads, probes and clips
- Fluke TL220 SureGrip™ Industrial Test Lead Set
- Fluke AC285 SureGrip™ Alligator Clips
- Fluke AC87 Heavy Duty Bus Bar Clip Set
- Fluke TL223 SureGrip™ Electrical Test Lead Set
- Fluke TL71 Premium Test Lead Set
- Fluke TL175 TwistGuard™ Test Leads
- Fluke TL75 Hard Point™ Test Lead Set
- Fluke TL224 SureGrip™ Insulated Test Leads
- Fluke TLK-220 SureGrip™ Industrial Test Lead Kit
- Fluke TLK-225 SureGrip Master Accessory Set
- Fluke TP220 SureGrip™ Industrial Test Probes
- Fluke TP1 Slim Reach Test Probes
- Fluke TL175-HV CAT III 1500 V TwistGuard™ Test Leads
Lights
- Fluke LVD1A Non-Contact Voltage Tester with LED Flashlight
- Fluke L206 Deluxe LED Hat Light
Probes
- Fluke 80PK-9 General Purpose Probe
- Fluke 80PK-8 Pipe Clamp Temperature Probe
- Fluke 80PK-27 SureGrip™ Industrial Surface Temperature Probe
Thermometer
- Fluke 80TK Thermocouple Module
Adapters and cables
- Fluke 80AK-A Thermocouple Adapter
Current clamps and probes
- Fluke i1010 AC/DC Current Clamp
For more information, click here.
Manuals
- 116 | Users manual
- 116C | Users manual
- 114, 115, 116, and 117 | Calibration information
- 114, 115, 116, and 117 | Calibration information supplement
- 117, 116,115,114,113 and 110 Plus | Statement of memory volatility
Data Sheets
- Add wireless to your Fluke digital multimeter
- Extended Specs For 114, 115, 116, 117
- Fluke 116 Multimeter Data Sheet