Fluke 773 Milliamp Process Clamp Meter
Sku: FLK-773
Price: R57488,50 incl Vat
Fluke 773 Milliamp Process Clamp Meter
Product Information
Save time by NOT breaking the loop on 4-20 mA signal measurements.
ARE YOU SPENDING TIME:
- Taking mA measurements by removing a wire and breaking the loop
- Calling the control room to isolate a loop
- Testing analog input/output on a console
- Troubleshooting devices with mA inputs and outputs
- Repairing intermittent or erratic 4-20 mA loops
- Going back to the shop to get extra tools
If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters . It's designed to save you time, and money, by eliminating time-wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.
Here are some specific ways the Fluke 773 Clamp Meters will help you:
Milliamp Clamp Features |
Application |
How it saves time and money |
Measure mA signals for PLC and control system analog I/O without breaking the loop. |
Measures low level dc current |
Correlate process indication with real physical value |
Measure output signals from transmitters without breaking the loop |
Maintain and troubleshoot process and automation equipment without breaking the loop |
No disruption to the process |
Detachable clamp with extension cable |
Measurements in tight locations |
Enables measurements in difficult situations |
Source, simulate and measure mA signals in circuit (break the loop) |
Confirm non-contact measurement. ve the next tool in hand for troubleshooting (source simulate) |
Eliminates the need to return to the shop to get a loop calibrator for troubleshooting after finding a bad signal with non-contact measurement |
Source and measure VDC |
Troubleshoot voltage input and output devices. |
Measure presence of 24V loop power. Measure 1 to 5 or 0 to 10V process signals. Test chart recorders |
4 to 20 mA In/out |
Dual channel mA source and measurement for troubleshooting |
Source 4 to 20 mA signals into valves and mA signal conditioners and simultaneously measure 4 to 20 mA positioning output signals. |
4 to 20 mA scaled output |
Scaled mA output provides a mA signal output representative of the measured mA value |
Connect a logging DMM and log the mA signal without breaking the loop |
Loop power supply |
Power a transmitter |
Substitute testing of the installed 24V loop power supply. Power a transmitter and measure its mA output signal for troubleshooting. |
Dual backlit display with both mA measurement and percent of 4 to 20 mA span |
Clear measurement presentation |
Allows quick measurement evaluation |
Measurement Spotlight |
Illuminates hard to see wires in dark enclosures |
Measurement process is easier and quicker |
Measure up to 99.9 mA range non-contact |
Wide range of measurements |
Measures 10 to 50 mA signals in older control systems |
Automatic power off |
After 15 minutes and 2 minute automatic off for backlight and spotlight |
Saves battery life |