Ideal for cleanroom environments and demanding calibration workCleanroom-Compatible, Ultra-Portable, and Fast

Traditional calibration baths are known for stability and uniformity—but they’re far from ideal for cleanroom use. Their large size, fluid handling requirements, and potential for spills or vapors make them a poor fit for controlled environments.The Fluke 9190A Ultra-Cool Field Metrology Well offers a smarter solution. Designed specifically for cleanrooms and critical process industries, it provides:

  • Wide temperature range suitable for pharmaceutical, biomedical, and food processing needs
  • Compact, lightweight design for easy transport and field use
  • No heat transfer fluids, keeping your environment contaminant-free
  • Faster heating and cooling times than traditional calibration baths—so you complete calibrations faster

Precision You Can Trust for Process Accuracy

Accurate process measurements are essential for quality control. Inaccurate data can lead to product recalls, regulatory penalties, lost profits, and reputational damage. That’s why your calibration equipment needs to be just as dependable as your measurement systems.The 9190A Ultra-Cool Field Metrology Well delivers:

  • Best-in-class accuracy, stability, and uniformity
  • Designed using decades of Fluke dry-block technology expertise
  • Conformance to EURAMET cg-13 best practices for temperature block calibrators
  • Thoroughly tested specs for axial and radial uniformity, hysteresis, and loading effects

Make Every Measurement CountWhen you use the 9190A, you’re choosing the most accurate and stable ultra-cool dry-block calibrator available. That confidence translates into better product quality, more efficient compliance, and measurable business impact.

  • Wide temperature range: –95 °C to 140 °C.
  • Excellent accuracy
  • Accuracy using built-in reference thermometer readout: ± 0.05 °C full range.
  • Display accuracy: ± 0.2 °C full range.
  • Best-in-class stability: ± 0.015 °C full range
Specifications
Temperature range at 23°C –95°C to 140°C (–139°F to 284°F)
Display accuracy ±0.2°C full range
Accuracy with external reference3 ±0.05°C full range
Stability ±0.015°C full range
Axial uniformity at 40 mm (1.6 in) ±0.05°C full range
Radial gradient ±0.01°C full range
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.006°C full range
(versus display with one 6.35 mm probe)
±0.25°C at –95°C
±0.10°C at 140°C
Operating conditions 0°C to 35°C, 0% to 90%
RH (non-condensing) < 2000 m altitude
Environmental conditions for all specifications except temperature range 13°C to 33°C
Immersion (well) depth 160 mm (6.3 in)
Well diameter 30 mm (1.18 in)
Heating time1 –95°C to 140°C: 40 min
Cooling time1 23°C to –90°C: 80 min
23°C to –95°C: 90 min
140°C to 23°C: 60 min
Stabilization time2 15 min
Resolution 0.01°
Display LCD, °C or °F user selectable
Size (H x W x D) 480 x 205 x 380 mm (18.8 x 8.0 x 14.9 in)
Weight 16 kg (35 lb)
Power requirements 100 V to 115 V (±10%) 50/60 Hz, 575 W
200 V to 230 V (±10%) 50/60 Hz, 575 W
System fuse ratings 115 V: 6.3 A T 250 V
230 V: 3.15 A T 250 V
4–20 mA fuse (-P model only) 50 mA F 250 V
Computer interface RS-232, and USB Serial included
Safety IEC 61010-1, Installation Category II, Pollution degree 2
Electromagnetic environment IEC 61326-1: Basic
Refrigerants R32 (Difluoromethane)
< 20 g, ASHRAE safety group A2L
R704 (Helium)
< 20 g, ASHRAE safety group A1
-P Specifications
Built-in reference thermometer readout accuracy (4-wire reference probe)3 ±0.010°C at –95°C
±0.013°C at –25°C
±0.015°C at 0°C
±0.020°C at 50°C
±0.025°C at 140°C
Reference resistance range 0 Ω to 400 Ω
Reference resistance accuracy4 0 Ω to 42 Ω: ±0.0025 Ω
42 Ω to 400 Ω: ±60 ppm of reading
Reference characterizations ITS-90, CVD, IEC-751, resistance
Reference measurement capability 4 wire
Reference probe connection 6-pin din with INFO-CON technology
Built-in RTD thermometer readout accuracy NI-120: ±0.015°C at 0°C
PT-100 (385): ±0.02°C at 0°C
PT-100 (3926): ±0.02°C at 0°C
PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range 0 Ω to 400 Ω
Resistance accuracy4 0 Ω to 25 Ω: ±0.002 Ω
25 Ω to 400 Ω: ±80 ppm of reading
RTD characterizations PT-100 (385), (JIS), (3926), NI-120, resistance
RTD measurement capability 2-wire, 3-wire, and 4-wire RTD with jumpers only
RTD connection 4-terminal input
Built-in TC thermometer readout accuracy5 Type J: ±0.70°C at 140°C
Type K: ±0.75°C at 140°C
Type T: ±0.60°C at 140°C
Type E: ±0.60°C at 140°C
Type R: ±1.60°C at 140°C
Type S: ±1.60°C at 140°C
Type M: ±0.65°C at 140°C
Type L: ±0.65°C at 140°C
Type U: ±0.70°C at 140°C
Type N: ±0.75°C at 140°C
Type C: ±1.00°C at 140°C
TC millivolt range –10 mV to 75 mV
Voltage accuracy 0.025% of reading +0.01 mV
Internal cold junction compensation accuracy ±0.35°C (ambient of 13°C to 33°C)
TC connection Miniature connectors (ASTM E1684)
Built-in mA readout accuracy 0.02% of reading + 0.002 mA
mA range Cal 4-22 mA, Spec 4-24 mA
mA connection 2 terminal input
Loop power function 24 V DC loop power
Built-in electronics temperature coefficient
(0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
1. For ambient temperature of 23°C.
2. Time from when the SETPOINT is reached to when the unit is with in stability specification.
3. The temperature range may be limited by the reference probe connected to the readout.
The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.
4. Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
5. The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz.

Accessories common to all models:

Accessory Description
9190-INSA Insert “A” 9190A, imperial miscellaneous holes
9190-INSB Insert “B” 9190A, imperial comparison holes
9190-INSC Insert “C” 9190A, 0.25 inch holes
9190-INSD Insert “D” 9190A, metric comparison holes
9190-INSE Insert “E” 9190A, metric miscellaneous holes with 0.25 inch hole
9190-INSF Insert “F” 9190A, metric comparison miscellaneous holes with 0.25 inch hole
9190-INSZ Insert “Z” 9190, blank
9190-INSTC TC insert, 9190A, RADIAL GROOVES, WITH INSULATOR
9190-INSY1 Insert “Y1” 9190A, custom insert with blank insulator.
9190-INSY2 Insert “Y2” 9190A, custom insert with custom insulator.

 

9190-CASE Carrying Case, 9190A Ultra-Cool Field Metrology Well