Fluke Networks DSX CableAnalyser Series

Product Information

The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

ProjX™ Management System Manages Complex Jobs with Ease – Manage up to 12,000 Cat 6A test results with full graphics

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX CableAnalyzer Series copper cable certifiers provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The “Fix Later” selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.

Project Setup screen

Project menu screen shows
percent complete per job.

Arrow
Project Menu Screen

Specific screen shows up to the minute project details.

Arrow
Project Test Setup Screen

Set-up or view test limits, and
testing attributes.

Taptive™ User Interface Simplifies Set Up, Eliminates Errors and Speeds Troubleshooting – Capacitive touchscreen allows quick tester setup and supports all standards

Taptive user interface is easy enough for even the newest technician to perform tests across multiple media types and testing requirements. The capacitive Taptive user interface makes all jobs easily accessible from the menu screen. Touch the job you’re working on and the large display confirms the test that needs to be performed, animated instructions simplify setting the configuration making correct testing assured.

 

Taptive User Interface Screen
Simple Set up.

LinkWare™ PC Cable Test Management Software

Leveraging the popular and multi-featured LinkWare PC management software application, DSX CableAnalyzer Series users can easily access the ProjX management system data, generate reports, and upgrade the software in their testers. Project Managers have full capabilities to manage workflow and consolidate test results. Users can provide the finishing touch by adding their company logo to the report and offer it unaltered to their customers for system acceptance purposes. Keep your business tools simple, no matter which Fluke Networks copper or fiber tester you are using, LinkWare PC is the software package that reports it all.

Now with LinkWare PC stats, the new automated statistical report option, you can move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare PC test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.

LinkWare™ PC Cable Test Management Software Screen LinkWare Stats Screen
New versions of LinkWare PC are always backwards compatible with previous versions, so you can stay current and always integrate tests from different testers into one test report. LinkWare Stats summarizes all project data

Versiv Platform is Ready for Today’s and Tomorrow’s Jobs

Electrically centered plug design is compliant with TIA Level 2G and IEC Level VI accuracy requirements to 2000 MHz with a future-ready design to support all hardware upgrades

The DSX CableAnalyzer Series enables cable testing and certification for network deployments up to 40 Gigabit Ethernet – whether it is an existing Cat 5e, 6, 6A, 8 or Class I/II cabling system, the DSX tests to all industry standards. The electrically centered test plug results in the Level 2G/VI accuracy required to support field testing to Cat 8 / Class I/II, 2000 MHz. The DSX exceeds the IEC Level VI and TIA Level 2G specifications assuring you of higher confidence in results over the full frequency range. Higher performance cabling systems like Cat 8 require more precise measurement to ensure they are providing the noise immunity required by 25G and 40G applications. Additionally, complex Alien Crosstalk link-to-link certification is simplified by integrating the measurement capability into each copper module up to 40GBASE-T testing.

The DSX is the first field tester to support balance measurements including Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). TCL and ELTCTL are important measurements found in the cabling standards. They define a minimum performance for balance, a key parameter to help determine noise immunity. Industrial network owners/operators are especially interested in this property due to the higher level of electromagnetic interference (EMI) within the industrial environment.

Fluke Networks’ DSX CableAnalyzer Series has obtained Intertek (ETL) verification in accordance with the ANSI/TIA-1152-A specification for Level 2G test equipment. (Report on file.)

TLC and ELTCTL Graph View

Performs with Unsurpassed Speed

Eight second Cat 6A test time and the fastest way to submit your certification results

No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 8 seconds or certify two fibers at two wavelengths in just 3 seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

Passing Test Results
Troubleshoot Like an Expert

Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting

The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are located on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer Series removes this limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.

HTDTX shows the far end connection is clearly the issueHigh Definition Time Domain Crosstalk (HTDTX) shows the far end connection in clearly the issue Feature Simple DiagnosticsFeatures simple diagnostics based decades
of Fluke Networks troubleshooting experience.

Shield continuity historically is a direct current (DC) measurement with no distance to fault available. Other testers run a simple resistance test to verify that the shield has continuity. These tests have been shown to be inaccurate, sometime confusing a ground path as shield continuity and not correctly identifying a break in the shield. Other testers may tell you there is a break in a shield, but not pinpoint the exact location giving no indication of where to start rework. The DSX CableAnalyzer Series is the first field tester to report distance to any shield integrity issues, reporting the true status of the screen continuity. This is especially important in\ datacenters and Cat 8 installations where screen continuity is critical to maintaining alien crosstalk performance of screened cabling.

Wiremap Shows Distance to fault, break and short
Wiremap – shows distance to fault, break and short

Comparing the DSX-8000 and DSX-5000

he DSX CableAnalyzer Series family copper cable certifier is based on two modules: the DSX-5000 and DSX-8000. The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.

Copper Certification
DSX-8000 CableAnalyzer™ DSX-5000 CableAnalyzer™
Category 6A / Class EA test time 8 seconds 10 seconds
Category 8 / Class I/II test time 15 seconds
HDTDX/HDTDR diagnostic test times ≈ 3 seconds ≈ 3 seconds
Internal memory ≈ 5,000 Cat 8 with plots
≈ 12,000 Cat 6A with plots
≈ 12,000 Cat 6A with plots
Level V Accuracy (1 GHz)
Level VI/2G Accuracy (2 GHz)
Resistance Unbalance measurement
Shield integrity check
TCL measurement
ELTCTL measurement
CDNEXT measurement
CMRL measurement
Built in Alien XTalk module
Channel Adapter 2 GHz Range 1 GHz Range
Permanent Link Adapter 2 GHz Range 1 GHz Range
Optional Accessories
Patch cord adapters Category 5e, 6 and 6A patch cord Category 5e, 6 and 6A patch cord
Coax Adapter
M12 Adapter
TERA Adapter
GG45 Adapter

Validate that cables conform to international standards

The DSX2-5-IE-K1 provides complete testing for copper cabling from single pair to Cat 6A, and includes adapters for RJ-45, M12-D and M12-X. Approved by over 30 cabling manufacturers.

  • Startup faster: Ensure cable performance at machine builder, commissioning and after making changes
  • Prevent downtime: Find marginal cables susceptible to vibration, moisture, noise and temperature
  • Speed troubleshooting: Avoid wasting time installing bypass cables. Identify the exact type and location of cable failure—or prove it’s good
  • Supports cabling for EtherNet/IP™, PROFINET, ModBus TCP™ and other protocols. Supports RJ45 and M12 connectors

Support for M12 and ix Industrial® Connectors

The DSX Series offers adapters for industrial connectors, including

  • M12D code (2 pair)
  • M12X code (4 pair) – Endorsed by Panduit
  • Ix Industrial® – Test Adapters available from HARTING and HIROSE

Unique Features:

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  • ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Standards:

    • Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
    • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) –IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
    • TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Published Sep 2019 )
    • Screen continuity along path of cabling

Performance:

  • Eight second Cat 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 Cat 6A test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  • Integrated Wi-Fi allows you to easily upload results to LinkWareTM Live
  • Over 1 billion links reported on LinkWare PC management software

 

Cable Types

 

Shielded and unshielded pair LAN cabling

 

TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent link adapters

 

Plug type: shielded RJ45
Optional Plug type: Tera

 

Channel Adapters

 

Jack type: shielded RJ45
Optional Jack type: Tera, GG45

 

Test Standards

 

TIA

 

Category 3, 4, 5, 5e, 6, 6A, 8 per ANSI/TIA-568.2-D

 

ISO/IEC

 

Class C and D, E, EA, F, FA and I/II certification per ISO/IEC

 

Maximum frequency

 

DSX-8000: 2000 MHz;
DSX-5000: 1000 MHz

 

General Specifications

 

Speed of Autotest

 

DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA8 seconds. Full 2-way Autotest of Category 8: 16 seconds

DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds

 

Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests)

 

Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT),Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL)

 

Input protection

 

Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage

 

Display

 

5.7 in LCD display with a projected capacitance touchscreen

 

Case

 

High impact plastic with shock absorbing overmold

 

Dimensions

 

Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)

 

Weight

 

Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)

 

Main unit and remote:

 

Lithium ion battery pack, 7.2 V

 

Typical battery life:

 

8 hours

 

Charge time*

 

Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.

 

Languages supported

 

English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian

 

Calibration

 

Service centre calibration period is 1 year

 

Integrated Wi-Fi

 

Integrated Wi-Fi

 

Environmental Specifications
Operating Temperature

 

32°F to 113°F (0°C to 45°C)

 

Storage Temperature

 

-14°F to +140°F (-10°C to +60°C)

 

Operating relative humidity

 

0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)

 

Vibration

 

Random, 2 g, 5 Hz-500 Hz

 

Shock

 

1 m drop test with and without module and adapter

 

Safety

 

CSA 22.2 No. 61010, IEC 61010-1 3rd Edition

 

Operating altitude

 

13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter

 

EMC

 

EN 61326-1

 

Performance Specifications **

 

DSX-8000

 

Category 8 test modes (or lower link categories)
Class I/II test modes

 

ANSI/TIA-1152 Level 2G
Proposed standard IEC 61935-1 Ed. 5 Level VI

 

DSX-5000

 

Category 6A/Class EA test modes (or lower link categories)
Class FA test modes

 

Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Exceed Level V requirements as in the draft 4th edition of IEC 61935-1.

 

Length of Twisted Pair Cabling1

 

Without Remote or in DSX-5000 Long Communication Mode

 

With Remote

 

Range

 

800 m (2600 ft)

 

150 m (490 ft)

 

Resolution

 

0.1 m or 1 ft

 

0.1 m or 1 ft

 

Accuracy

 

± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m

 

± (0.3 m + 2 %)

 

Propagation Delay

 

Without Remote or in DSX-5000 Long Communication Mode

 

With Remote

 

Range

 

4000 ns

 

750 ns

 

Resolution

 

1 ns

 

1 ns

 

Accuracy

 

± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns

 

± (2 ns + 2 %)

 

Delay Skew

 

Range

 

0 ns to 100 ns

 

Resolution

 

1 ns

 

DC Loop Resistance Test

 

Range

 

0 Ω to 540 Ω

 

Resolution

 

0.1 Ω

 

Accuracy

 

± (1 Ω + 1 %)

 

Overload recovery time

 

Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.

 

For more information please click here