The INCON® Distribution Transformer Monitor (DTM) provides continuous, meter-grade precision performance monitoring of high-value, mission-critical, low-voltage pad mount and conventional pole mount transformers.
Product Information
DATA-DRIVEN DECISION MAKING
With the ability to monitor and trend transformer output voltage, loading (current) by phase, temperature, and Power Factor for an entire network of transformers, utilities are armed with powerful information regarding power distribution and equipment maintenance.
![]() |
CUSTOMIZED ALARMS & NOTIFICATIONS Via the CONVERGE™ web interface, utilities can be managed by exception with customized threshold alarms and notifications:
|
![]() |
TRANSFORMER LIFE PREDICTION By continuously monitoring the key indicators of a transformer’s performance, including temperature and load, the DTM not only tracks the loss of life in a transformer but also employs advanced predictive algorithms to forecast the estimated remaining run time. CONTINUOUS MONITORING
|
![]() |
UNITE™ ASSET MANAGEMENT DATABASE A secure MQTT communication protocol allows the DTM to communicate with the web-based UNITE™ asset management database safely. UNITE™ provides user-friendly access to all distribution transformer performance data for convenient centralized analysis and reporting. ASSET MANAGEMENT
|
![]() |
EASY INSTALLATION The DTM can be applied to any distribution transformer with a secondary output of 480 volts or less, phase to neutral. This includes single-phase, split-phase, or three-phase transformers. Installation has been kept simple, with only a few connections required to the transformer secondary. SIMPLE CONNECTIONSFour split-core Rogowski Coils measure load current. Five voltage leads measure Phase A, Phase B, Phase C, and neutral and ground. Two magnetically mounted RTD sensors measure the top and bottom transformer temperatures. MAGNETIC MOUNTINGFour powerful 25 lbs. magnets integrated into the mounting plate allow the DTM to be installed vertically or horizontally without any drilling or adhesives. SETUP & CONFIGURATIONAll user interface communication, including configuration of alarms and settings, data viewing, and alarm resetting, is made via the CONVERGE™ web interface. Configuration can be done locally via Wi-Fi using a web browser or remotely through the cellular connection. |
TRANSFORMER STATE-OF-HEALTH
By continuously monitoring the key indicators of a transformer’s performance, including temperature and load, the DTM provides remote access to real-time transformer health data and automated threshold alarms for condition-based maintenance planning.
![]() |
TRANSFORMER STATE-OF-HEALTHBy continuously monitoring the key indicators of a transformer’s performance, including temperature and load, the DTM provides remote access to real-time transformer health data and automated threshold alarms for condition-based maintenance planning. |
![]() |
TRANSFORMER LIFE PREDICTION The DTM not only tracks the loss of life in a transformer but also employs advanced predictive algorithms to forecast the estimated remaining run time. The DTM ensures a near-constant assessment of the transformer’s health, considering real-time conditions and applying a calculated dynamic acceleration factor to predict the cumulative loss of life accurately. |
![]() |
POWER FACTOR MONITORINGThe DTM provides a transformer’s Power Factor, which is a trend of useful power delivered. Power Factor helps utilities to determine the most efficient distribution of power during peak times and to ensure the delivery of high-quality outbound power when their customers need it the most. |
![]() |
HIGH PERFORMANCE HARDWAREA powerful industrial IOT grade processor and sophisticated polyphase energy measurement integrated circuit provide superior on-board computation capability and Power Quality Monitor level fidelity. |
![]() |
DEPLOY ANYWHERE AT SCALEA built-in Cat M1/NB2 cellular modem allows the DTM to communicate via a cellular network, enabling utilities to deploy DTMs virtually anywhere and at scale (i.e. one unit to thousands of units). |
Components & Dimensions |
1. IP68 weather-proof enclosure 2. Voltage leads (5) 3. Split-core Rogowski coils (4) 4. RTD temperature sensors (2) 5. Cable strain relief 6. Status indicator LED 7. Ethernet port (optional) |
||||||||||||||||||||||||||||||||||||
Transformer Monitor |
Applications
Distribution Transformer Monitoring Reporting
Power Source
Temperature Sensors
Current Sensors
Fuses
|
||||||||||||||||||||||||||||||||||||
Environmental |
Enclosure Rating
Operating Temperature/Humidity: -40°C to +60°C / 0 – 90% RH Storage Temperature/Humidity Range: -40°C to +85°C / 0 – 95% RH |
||||||||||||||||||||||||||||||||||||
Communications |
Local Communication: Wi-Fi (TCP/IP) User Interface: Embedded web server running on Linux platform accessible via standard web browser Protocols: MQTT Embedded Device Options: Cat M1 Cellular LED Indicator: Tri-color LED to indicate running and alarm states (can be deactivated) |
||||||||||||||||||||||||||||||||||||
Mechanical |
Size (W x L x H): 6.25" x 7.75" x 3.75" Weight: 5.5 Lbs. Mounting: Magnet-mount is provided; pole-mount kit is available. |
||||||||||||||||||||||||||||||||||||
Standards | IEC 61010 CAT IV 480V | ||||||||||||||||||||||||||||||||||||
Measured Parameters |
|
||||||||||||||||||||||||||||||||||||
Communication | All User Interface communication including configuration of alarms and settings, data viewing and alarm resetting can be done locally via Wi-Fi using a web browser or remotely via the cellular connection. |
Model | Description |
---|---|
DTM-4-VZ | Distribution Transformer Monitor with Verizon® Sim Card |
DTM-4-ETH | Distribution Transformer Monitor with Ethernet |
UNITE-1 | UNITE™ 3-month subscription equaling one unit (1 device, up to 10 users) |
Included Hardware
- Voltage leads (5)
- Split-core Rogowski coils (4)
- RTD temperature sensors (2)
- Magnet mount