The INCON® Optimizer3 Circuit Breaker Monitor delivers advanced automated reporting of all critical circuit breaker diagnostics to ensure uptime and facilitate predictive maintenance. The Optimizer3 is ideal for high-voltage, live or dead-tank, oil, vacuum or gas circuit breakers.
EXTEND THE LIFE OF YOUR CIRCUIT BREAKER- With early circuit breaker problem detection and automated system performance evaluation, the Optimizer3 provides utilities with the tools to help improve efficiency, extend equipment service life, and enhance reliability of their systems.
24/7 REAL-TIME ANALYSIS- The web-based software provides monitoring data on both the mechanical and electrical performance of a circuit breaker, delivering trending analysis that predicts the date of future service.
CONDITION BASED MAINTENANCE- Armed with a high degree of circuit breaker performance insight from the Optimizer3, utilities can deploy maintenance with intelligence and only as needed – limiting truck roles, speeding reaction time, and lowering overall maintenance costs.
BREAKER TIMING- In the milliseconds it takes for a circuit breaker to trip, the Optimizer3 collects a full battery of timing data including opening (trip) time, clearing time, arc duration, and opening/closing travel times and velocities are automatically analyzed to provide a full assessment of the circuit breaker’s health.
SF6 REPORTING-The Optimizer3 aids in the mandatory compliance reporting required by the EPA, resources boards, and other regulatory agencies by monitoring for SF6 gas leaks and related indicators and automatically reporting any fugitive emissions.
COMPLETE CIRCUIT BREAKER DIAGNOSTICS- With 8 sensor inputs, 5 timing inputs, and an onboard ambient temperature sensor and supply voltage monitor, the Optimzer3 and its array of sensors deliver a complete diagnostics report of a circuit breaker’s performance. Utility technicians are empowered with the data to repair a small issue before it causes a substantial failure that may require equipment replacement or even an entire overhaul of a high-cost asset.
VOLTAGE & CURRENT MONITORING-Real-time voltage and current are measured with an array of high-accuracy, loop-powered voltage and current transducers. Applications include motor current, station battery voltage, heater current, and compressor run-time.
SF6 GAS MONITORING- SF6 gas density, pressure, and dew point sensors and fill point adapters aid in the mandatory compliance reporting required by the EPA, resources boards, and other regulatory agencies by monitoring for SF6 gas leaks and related indicators and automatically reporting any fugitive emissions.
SF6 GAS HUMIDITY ABSORBER-The SF6 gas humidity absorber is capable of passively absorbing up to 40 milliliters of water from SF6 gas, saving major expense compared to standard circuit breaker moisture removal. The corrosion-resistant absorber is easily connected to a circuit breaker's SF6 gas port.
TANK HEATER MONITORING-The Optimizer3 monitors the tank heater’s supply current using a universal power status monitor. If one or more of the heater elements fails, the Optimizer3 will assert a heater alarm.
REMOTE WEB INTERFACE-The web-based interface allows users to securely connect directly to the Optimizer3 monitoring and alarm data from any web-enabled device without having to host anything on a server.
DATA COMMUNICATION- Performance data is delivered through standard network communication protocols to maintenance, reliability, and environmental protection stakeholders with role-based access and permissions.
SETUP & CONFIGURATION- Remotely setup and program, clear and reset alarms, install firmware upgrades. Personnel can also save, download and copy configurations between breakers.
REPORTING- Circuit breaker performance and SF6 gas compliance reports for regulatory agencies can be easily generated and exports in CSV format.
Specifications
Circuit Breaker Monitoring Capabilities
- Breaker State (Open/Closed)
- Breaker Timing
- Opening & Closing Time (Latch Time)
- Opening & Closing Travel Time
- Arc Time
- Interrupting Time
- Opening & Closing Travel Velocity
- Operations Count
- Fault-Interrupt Count
- Non-Fault-Interrupt Count
- Days Since Last Operation
- Trip & Close Coil Circuit Integrity
- Charging Motor Current Draw & Run Time
- Contact Wear & Restrike Detection
Circuit Breaker Monitoring Reporting
- 2-Hour Current Log (5000 Records – FIFO)
- Min., Max., & Average Current
- Event History (5000 Records – FIFO)
- Opening Coil (1 or 2)
- Timing Measurements
- Opening & Closing Velocity
- Peak Fault Current
- Alarm Status for Each Operation
- Contact Wear for Each Operation
- Accumulated Contact Wear
SF6 Gas Monitoring Capabilities
- Gas Density
- Gas Pressure
- Gas Temperature
- Leakage Trend & Confidence Level
- Forecasts Days until Low Gas Alarm
SF6 Gas Monitoring Reporting
- Daily Average (750 Records – FIFO)
- Pressure, density, temperature & SF6 mass
- 2-Hour History Log (5000 Records – FIFO)
- Pressure, density, temperature
Sensor Types Supported
- SF6 Gas Density, Temperature, Pressure
- SF6 Gas Dew Point
- Generic AC/DC Voltage & Current
- Generic (Hydraulic, Air) Pressure
- Generic Temperature
- Tank Heaters (UPSM-241)
- Analog: 4-20mA (Loop-Powered)
- Digital: Frequency/Pulse-Width Modulated
Immunity and Emissions Certification
- CISPR 16-2-1 (Conducted Emissions)
- CISPR 16-2-3 (Radiated Emissions)
- IEC61000-4-2 (ESD)
- IEC61000-4-3 (Radiated RF)
- IEC61000-4-4 (EFT)
- IEC61000-4-5 (Surge)
- IEC61000-4-6 (Conducted RF)
- IEC 61000-4-11 (Voltage Dips & Interrupts)
- IEC 61000-4-12 (Damped Osc. Wave, Power Ports)
- FCC Part 15, Subpart B; ICES-003 (Emissions)
Specifications
| Environmental | Operating Temperature: -40 to 65° C Storage Temperature: -40 to 65° C Humidity: 0 to 95% Non-condensing |
| Communications | RS-485 Full/Half Duplex Ethernet Fiber-optic |
| Relay Output | Dry Contact; 1 ea. Form C |
| Relay Contact Rating | N.O: 5 Amps @ 250 VAC or 3 Amps @30 VDC N.C: 2 Amps @ 250 VAC or 1 Amp @ 30 VDC |
| Relay Contact Fuses | 3.15 A Slow-Blow |
| Power Supply Input Voltage | 110-250 VDC / 90-264 VAC, 50 / 60 Hz |
| Power Consumption | 60VA Maximum |
| Power Supply Input Fuses | 3.15 A Slow-Blow |
| Aux Input Voltage | 0 to 48 – 250 VDC |
| Aux Input Fuses | ¼ A Fast-Blow |
| Aux Input Impedance | 540K Ohms |
| CT Pickup Coil Input Signal | 0 to 5 VAC |
| Input Sampling Rate | 32 Samples per line cycle |
| Sensor Signal | Analog: 4 to 20 mA Digital: Frequency & Pulse-Width Modulated |
| Sensor Power | 20 VDC @ 25mA Max |
| Analog Sensor Accuracy | +/-1% of Full-Scale Max, +/-0.5% Typ. |
| Dimensions | 280 mm L x 70 mm W x 143 mm H 11" L x 2¾" W x 5 5/8" H |
| Shipping Weight | 6 lbs. (2.25Kg) |
COMMUNICATION
The Optimizer3 functions as a web server itself, with no additional software required for communication. It is connected to a network via either a fiber optic, Ethernet or RS-485 connection to facilitate the transfer of data. The web-based interface allows users to securely connect directly to the Optimizer3 data from any web-enabled device without having to host anything on a server.
Remote Functions
- Setup
- Programming
- Alarm clearing
- Alarm resetting
- Firmware upgrades
Circuit Breaker Status
- Alarm status
- Date/time of last operation
- Operation number
- Real-time RMS current
Sensor Status
- SF6 gas compliance info
- Ambient temperature
- Supply voltage
- Sensor information
Setup & Configuration
- The completed configuration can be downloaded and saved as an XML file
- The configuration file can be edited with a word processor and uploaded to other Optimizer 3 units, enabling them to be quickly configured for breakers of the same type
Data Security
To accommodate the high level of importance power utilities place on security, the Optimizer3 employs a multitude of contemporary security methods to prevent unauthorized access to data including:
- Secure access via HTTPS port only
- Encrypted USB flash drive access
- 10-minute inactivity timeout
- No default passwords
- Generic feedback from failed logins
- Hidden password characters
- Successful third party vulnerability threat testing:
- San Diego Gas & Electric
- Lower Colorado River Authority
OPTIMIZER3 CIRCUIT BREAKER MONITORS
| Model | Description |
|---|---|
| OM3D | Optimizer3 circuit breaker monitor, density measurement-ready |
| OM3D-F | Optimizer3 circuit breaker monitor, density measurement-ready with fiber-optic communication port |
| OM-MMK | Optimizer3 magnetic mounting kit |
Magnetic Mounting Kit
- Non-drill, easy mounting to ferrous metal panels and enclosures
- NEMA cabinet rating is not compromised by having to drill
- All hardware included: (4) clip nuts, (4) screws, and (4) magnets
CURRENT TRANSFORMER PICKUP COILS
Current transformer pickup coils enable the Optimizer3 to measure real-time current flow in the bushing current transformer secondaries. The split-core design allows the pickup coils to be applied to secondaries of bushing current transformers without disassembling or disconnecting the cabling for fast and convenient installation. They are available in eight current ranges to accommodate all applications.
| Model | Description |
|---|---|
| CT-20 | Current transformer pickup coil, 20 Amps |
| CT-30 | Current transformer pickup coil, 30 Amps |
| CT-50 | Current transformer pickup coil, 50 Amps |
| CT-100 | Current transformer pickup coil, 100 Amps |
| CT-160 | Current transformer pickup coil, 160 Amps |
| CT-250 | Current transformer pickup coil, 250 Amps |
| CT-400 | Current transformer pickup coil, 400 Amps |
| CT-800 | Current transformer pickup coil, 800 Amps |
Specifications
- Current sensors are specifically designed for use with Optimizer CT input circuitry
- Includes 8' wire lead
- Accuracy greater than 1%
SF6 GAS MONITORING
The Optimizer3 aids in the mandatory compliance reporting required by the EPA, resources boards, and other regulatory agencies by monitoring for SF6 gas leaks and related indicators and automatically reporting any fugitive emissions.
SF6 GAS DENSITY SENSOR
| Model | Description |
|---|---|
| DSDP | Digital SF6 gas density sensor, temperature & density, 10 ft cable |
| DSDP-20 | Digital SF6 gas density sensor, temperature & density, 20 ft cable |
| DSDP-30 | Digital SF6 gas density sensor, temperature & density, 30 ft cable |
| DSCC | 1/2" NPT conduit fitting adapter |
Specifications
- Density range: 0 to 60 grams per liter (kg/m3) SF6
- Temperature range: -40 to 85 °C
- Mounting thread: Male 3/8" BSPP
- Seal: Neoprene O-Ring
- Accuracy: 1.8% of full scale max.; 1.0% of full scale typ.
- Temperature signal: +/- 1°C at ambient temperature +/- 3°C at -40 to 85 °C
- Output signal: Digital (frequency & pulse-width modulated)
- Supply voltage: 10 to 20 Volts DC
- Electrical connections: 2-wire
- Operating temperature -40 to 70 °C
- Operating pressure -1 to 20 Bar
SF6 GAS PRESSURE SENSOR
The SF6 gas pressure sensor measures the temperature-compensated pressure of SF6 gas. The temperature and the compensated pressure measurements are digitally transmitted over a two-wire, power-line-carrier interface.
| Model | Description |
|---|---|
| PSDP | Digital SF6 gas pressure sensor, temp & pressure, 5 meter cable |
| PSDP-10 | Digital SF6 gas pressure sensor, temp & pressure, 10 meter cable |
| OM-SC5 | 5 meter cable with 90 degree connector |
| OM-SC10 | 10 meter cable with 90 degree connector |
Specifications
- Pressure range: 0 to 10 Bar Abs at 20 °C compensated
- Temperature range: -40 to 85 °C
- Mounting thread: Male 3/8" BSPP
- Seal: Neoprene O-Ring
- Pressure accuracy: +/- 1% of full scale range at 85 °C +/- 2.2% of full scale range at -40 to 85 °C
- Temperature accuracy: +/- 3°C
- Output signal: Digital (frequency & pulse-width modulated)
- Supply voltage: 15 to 30 Volts DC
- Electrical connections: 2-wire
- Operating temperature -25 to 80 °C
- Operating pressure: 0 to 20 Bar absolute
SF6 GAS DEW POINT TEMPERATURE SENSOR
The SF6 gas dew point sensor measures the moisture content of SF6 gas. This solid-state sensor converts the measured dew point temperature to a milliamp analog signal.
| Model | Description |
|---|---|
| OM-DPS | Analog SF6 gas dew point temperature sensor, 5 meter cable |
| OM-DPS-10 | Analog SF6 gas dew point temperature sensor, 10 meter cable |
| OM-SC5 | 5 meter cable with 90 degree connector |
Specifications
- Temperature range: -60 to 20 °C
- Mounting thread: Male 3/8" BSPP
- Seal: Neoprene O-Ring
- Accuracy: +/-2 °C
- Output signal: 4-20 milliamp DC
- Supply voltage: 10 to 32 Volts DC
- Electrical connections: 2-wire
- Operating temperature -50 to 60 °C
SF6 GAS SENSOR FILL PORT ADAPTERS
SF6 gas sensor adapters allow the range of sensors to be directly connected to a circuit breaker via the SF6 gas fill port. Integrated check valves and O-Ring seals facilitate a tight connection, mitigating the risk of a gas leak.
| Model | Description |
|---|---|
| OM-DN8XV | SF6 gas (2) sensor adapter, cross valve, DN8 couplings |
| Model | Description |
|---|---|
| OM-MTV | SF6 gas sensor adapter, tee valve, Malmquist x DN8 couplings |
| Model | Description |
|---|---|
| OM-M2TV | SF6 gas sensor adapter, tee valve, Malmquist couplings |
| Model | Description |
|---|---|
| OM-DN8TV | SF6 gas sensor adapter, tee valve, DN8 couplings |
| Model | Description |
|---|---|
| OM-DN20TV | SF6 gas sensor adapter, tee valve, DN20 couplings |
SF6 GAS SENSOR PIPE FITTINGS
SF6 gas sensors can be installed directly into the ¼ pipe feeding the circuit breaker's pressure gauge using SF6 gas sensor pipe fittings. All gas connections must be checked for leaks if this method is used.
| Model | Description |
|---|---|
| OM-SAM | SF6 gas sensor pipe fitting for (1) sensor, Mitsubishi circuit breakers only |
| OM-SAM2 | SF6 gas sensor pipe fitting for (2) sensors, Mitsubishi circuit breakers only |
| OM-SAA1 | SF6 gas sensor pipe fitting for first sensor, ABB circuit breakers only |
| OM-SAA2 | SF6 gas sensor pipe fitting for second sensor, ABB circuit breakers only |
-
For ABB circuit breakers, if two SF6 gas sensors are required, an OM-SAA2 must be installed in addition to the OM-SAA1.
SF6 GAS HUMIDITY ABSORBER
The SF6 gas humidity absorber is capable of passively absorbing up to 40 milliliters of water from SF6 gas, saving major expense compared to standard circuit breaker moisture removal. The corrosion-resistant absorber is easily connected to a circuit breaker's SF6 gas port.
| Model | Description |
|---|---|
| OM-NM-DN8 | SF6 gas humidity absorber, DN8 coupling |
| OM-NM-DN20 | SF6 gas humidity absorber, DN20 coupling |
| OM-NM-MAL | SF6 gas humidity absorber, Malmquist coupling |
Specifications
- Pre-charge: Virgin SF6 gas
- Material: Anodized aluminum and stainless steel construction
- Dimensions: 152 mm length x 10 0mm diameter (6" length x 3.94" diameter)
- Weight: 1.68 kg (3.7 lbs.)
- Absorption capacity: 40 ml (0.85 fluid ounces) of water
Voltage & Current Monitoring
Real-time voltage and current is measured with an array of high-accuracy, loop-powered voltage and current transducers. Applications include motor current, station battery voltage, heater current, and compressor run-time.
AC VOLTAGE TRANSDUCER
The AC voltage transducer is a loop-powered Voltage Transducer for measuring alternating current. It accurately converts measured AC voltage to a 4-20 milliamp signal, which can be monitored by the Optimizer3.
| Model | Description |
|---|---|
| OM-ACVT | AC Voltage Transducer |
Specifications
- Input voltage range: 0 – 480 VAC
- Power supply voltage: 18 – 24 volts DC
- Voltage accuracy: +/-1% of full scale
- Isolation: 2,500 volts
AC LOW-CURRENT TRANSDUCER
The AC low-current transducer is a loop-powered current transducer for measuring 50/60Hz alternating current. This transducer accurately converts measured AC current to a 4-20 milliamp signal, which can be monitored by the Optimizer3.
| Model | Description |
|---|---|
| OM-ACLCT | AC Low Current Transducer |
Specifications
- Selectable input current range: 0 – 2, 0 – 5 amps
- Power supply voltage: 15 – 40 volts DC
- Current accuracy:
- +/-2% of full scale in the low current range
- +/-1% of full scale in the high current range
AC CURRENT TRANSDUCER
The AC current transducer is a loop-powered, split-core current transducer for measuring 50/60Hz alternating current. This transducer accurately converts measured AC current to a 4-20 milliamp signal, which can be monitored by the Optimizer3.
| Model | Description |
|---|---|
| OM-ACCT | AC Current Transducer |
Specifications
- Selectable input current range: 0 – 10, 0 – 20, and 0 – 40 amps
- Power supply voltage: 12 – 30 volts DC
- Current accuracy: +/-2% from 10% to 100% of full scale
DC VOLTAGE TRANDUCER
The DC voltage transducer is a loop-powered voltage transducer which accurately converts measured DC voltage to a 4-20 milliamp signal, which can be monitored by the Optimizer3.
| Model | Description |
|---|---|
| OM-DCVT | DC Voltage Transducer |
Specifications
- Voltage range: 0 – 150 VDC
- Power supply voltage: 12 – 32 volts DC
- Voltage accuracy: +/-0.1% of full scale (+/-0.15 volts)
DC CURRENT TRANSDUCER
The DC current transducer is a loop-powered current transducer for measuring direct current. This transducer accurately converts measured direct current to a 4-20 milliamp signal, which can be monitored by the Optimizer3.
| Model | Description |
|---|---|
| OM-DCCT | DC Current Transducer |
Specifications
- Selectable current input range: 0 – 5, 0 – 10, 0 – 20 & 0 – 40 amps
- Power supply voltage: 8 – 28 volts DC
- Current accuracy: +/-0.5% of full scale
- Output circuit isolation: 1,000 volts DC
TEMPERATURE SENSOR
The temperature sensor is a loop-powered sensor which accurately converts the measured temperature to a 4-20 milliamp signal, which can be monitored by the Optimizer3.
| Model | Description |
|---|---|
| OM-TS | TempSense temperature sensor |
Specifications
- Power supply voltage: 12 – 30 volts DC
- Temperature accuracy: +/-2% of full scale
- Temperature range: -40 °C to 120 °C
TANK HEATER MONITORING
The Optimizer3 monitors the tank heater’s supply current using a Universal Power Status Monitor. Tank heaters are thermostatically controlled, so they do not run continuously. The power status monitor is wired in to the heater supply circuit and enables the current draw of the heaters to be monitored only when they are turned on. If one or more of the heater elements fails, the current draw will be too low and the Optimizer3 will assert a heater alarm.
UNIVERSAL POWER STATUS MONITOR
The universal power status monitor enables the Optimzer3 to monitor the AC current draw of circuit breaker tank heaters, cabinet heaters, or other high-powered electrical loads through its sensor input channels.
| Model | Description |
|---|---|
| UPSM-241 | Universal power status monitor with AC current transducer |
Universal Power Status Monitor Specifications
- Coil voltage: 195 – 330 VAC
- Fuse rating: 3 amps
- Dimensions: 5.1" (130 mm) L x 5.1" (130 mm) W x 4" (102 mm) H
AC Current Transducer Specifications
- Selectable input current range: 0 – 10, 0 – 20, and 0 – 40 amps
- Power supply voltage: 12 – 30 volts DC
- Current accuracy: +/-2% from 10% to 100% of full scale
TRIP CIRCUIT ISOLATION
The OM-TCI is a cost-effective method of complying with the Northeast Power Coordinating Council’s regulation requiring physical isolation of critical circuits in medium and high voltage environments. OM-TCI is used to physically isolate dual trip circuits when used in conjunction with the Optimizer Circuit Breaker Monitor (OM3D / OM3D-F).
| Model | Description |
|---|---|
| OM-TCI | Trip circuit isolator, includes transmitter, receiver, and a fiber optic interconnect |
| OM-TCI-DIN | Trip circuit isolator DIN Rail mounting kit |
Specifications
- Dimensions: 5.8" (148 mm) L x 2" (53 mm) W x 5.8" (148 mm) H
-
AIR PRESSURE SENSOR
The PS10 monitors air pressure across a 0-10 Bar Absolute range with an accuracy of +/- 1.5%. The rugged, stainless steel PS10 outputs a 4-20 mA analog signal that is captured and interpreted by the OM3D breaker monitor.
Model Description OM-PS-10B Air Pressure Sensor Specifications
Pressure Range 0 to 10 Bar Absolute Mounting G1/4" Male British Standard Parallel Thread Seal Neoprene O-ring seal (provided) Accuracy ± 1.5% of full-scale range @ 20 °C Temperature Effect ± 0.025% of full-scale range per 1 °C Linearity Error ± 0.1% of full-scale range Output Signal Analog 4-20 milliamps Excitation Voltage 10 to 35 Volts DC Electrical Connections 2-Wire (5-meter cable provided) Operating Temperature -20 to +85 °C Over Pressure Limit 20 Bar Absolute Electrical Insulation 15KV, 50 Hz for 1 minute Material External Stainless Steel (AISI316) Weight 5.29 oz. (150 grams) Magnetic Mounting Kit
Model Description OM-MMK Optimizer3 magnetic mounting kit