PICO USB TC-08
Sku: PIC-TC-08
Price: R11167,65
Temperature measurement and recording with the TC-08 is very easy — simply plug the TC-08 into a USB port on your computer, plug in your thermocouples, and you are ready to go.
Product Information
8 channel thermocouple data logger
- 8 channel thermocouple data logger
- Measures from –270 to +1820 °C (–454 to +3308 °F)
- High resolution and accuracy
- Expandable to 20 units / 160 channels
- Supports all popular thermocouple types
- Fast sampling rate — up to 10 measurements per second (including CJC)
- USB connected and powered
- PicoLog 6 for Windows, macOS and Linux data logging software included
- PicoSDK drivers for Windows, macOS and Linux included
Wide temperature range
The TC-08 thermocouple data logger is designed to measure a wide range of temperatures using any thermocouple that has a miniature thermocouple connector. Pico supply a wide range of suitable thermocouples (see Accessories).
All popular types of thermocouple are supported, allowing an effective temperature range of –270 to +1820 °C (the actual temperature range depends on the thermocouple being used).
The built in Cold Junction Compensation (CJC) circuit can also be used as a 9th channel to measure room temperature.
Fast and accurate temperature data acquisition
With the TC-08 thermocouple data logger your temperature measurements can be made both fast and accurately.
The short conversion time of the TC-08 means up to 10 temperature measurements can be taken every second (cold junction compensation counts as an additional measurement), while the high (20-bit) resolution ensures that the TC-08 can detect minute changes in temperature. For popular Type K thermocouples the TC-08 can maintain a better than 0.025°C resolution over a –250 to +1370 °C range.
Also measure voltage and 4–20 mA current loops!
As well as measuring temperature with thermocouples, the terminal board allows other sensors with voltage or current outputs to be connected.
The optional Single-Channel Terminal Board (see Accessories) plugs into a channel on the TC-08 and turns it into a 20-bit high resolution data logger. Screw terminals allow wires to be attached to the data logger without soldering. The four input ranges (±50 mV, ±500 mV, ±5 V and 4-20 mA) allow a wide range of other sensors and signals to be measured.
All you need in one easy-to-use unit
Temperature data acquisition with the TC-08 is very easy — simply plug the TC-08 into a USB port on your computer (no external power required), connect your thermocouples, and you are ready to measure temperatures.
The easy-to-use PicoLog data acquisition software is supplied with the TC-08 — allowing you to start measuring and recording temperatures with the minimum effort. The intuitive user interface of PicoLog makes it easy for you to set how frequently you want to take a measurement, and the number of measurements you want to take.
Need more?…
If you need more than 8 channels just plug up to 20 TC-08s into a powered USB hub network connected to your PC for a total of 160 channels. You can even mix and match different data loggers and a selection of PicoScope oscillsocopes from the Pico range to build a flexible, expandable data acquisition system.
- 8 channel thermocouple data logger
- Measures from –270 to +1820 °C (–454 to +3308 °F)
- High resolution and accuracy
- Expandable to 20 units / 160 channels
- Supports all popular thermocouple types
- Fast sampling rate — up to 10 measurements per second (including CJC)
- USB connected and powered
- PicoLog 6 for Windows, macOS and Linux data logging software included
- PicoSDK drivers for Windows, macOS and Linux included
USB TC-08 Thermocouple Data Logger general specifications | |
---|---|
Number of channels (single unit) | 8 |
Maximum number of channels (using up to 20 TC-08s) |
160 |
Conversion time | 100 ms per thermocouple channel + 100 ms for cold junction compensation (CJC can be disabled if all channels used as voltage inputs) |
Temperature accuracy | Sum of ±0.2% of reading and ±0.5 °C |
Voltage accuracy | Sum of ±0.2% of reading and ±10 µV |
Overvoltage protection | ±30 V |
Maximum common-mode voltage | ±7.5 V |
Input impedance | 2 MΩ |
Input range (voltage) | ±70 mV |
Resolution | 20 bits |
Noise-free resolution | 16.25 bits |
Thermocouple types supported | B, E, J, K, N, R, S, T |
Input connectors | Miniature thermocouple |
PC requirements | |
---|---|
Minimum | Processor: 1 GHz. Memory: 512 MB. Free disk space: 32–bit: 600 MB, 64–bit: 1.5 GB. Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7, Windows 8 (not Windows RT) or Windows 10. Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, macOS. Ports: USB 1.1 port. |
Recommended | Processor: 1 GHz. Memory: 512 MB. Free disk space: 32–bit: 850 MB, 64–bit: 2 GB. Operating system: 32– or 64–bit edition of Microsoft Windows 7, Windows 8 (not Windows RT) or Windows 10. Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, macOS. Ports: USB 1.1 or higher. |
Environmental | |
---|---|
Operating temperature | 0 to 50 °C |
Operating temperature for stated accuracy | 20 to 30 °C |
Operating humidity | 5 to 80 %RH non-condensing |
Storage humidity | 5 to 95 %RH non-condensing |
Water resistance | Not water-resistant |
Physical properties | |
---|---|
Dimensions | 201 x 104 x 34 mm (7.91 x 4.09 x 1.34 in) |
Software | ||
---|---|---|
PicoLog for Windows | PicoLog data acquisition software can collect up to 1 million samples. Features include: Multiple views — view data as a graph, spreadsheet or text Parameter scaling — convert raw data into standard engineering units Math functions — use mathematical equations to calculate additional parameters Alarm limits — program an alert if a parameter goes out of a specified range IP networking — transfer measurements via a LAN or over the Internet Operating systems supported — Microsoft Windows XP (SP3) to Windows 10. Not Windows RT. |
|
PicoLog languages | Full support for: English, Français, Deutsch Menus and dialogs only for: Italiano, Español, Svenska |
|
Software Development Kit | Includes example code | |
Optional free software | Drivers for Linux and macOS |
Documentation languages | |
---|---|
User’s guide Programmer’s guide Installation guide |
English English English, Français, Deutsch, Italiano, Español, Svenska, Nederlandse, Dansk |
General | |
---|---|
Additional hardware (supplied) | USB 2.0 cable, user manuals |
PC interface | USB 1.1 |
Power requirements | Powered from USB port |
Compliance | European EMC and LVD standards FCC Rules Part 15 Class A |
Total satisfaction guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. |
Warranty | 5 years |
TC-08 resolution
Thermocouple type | Overall range °C | 0.1 °C resolution | 0.025 °C resolution |
---|---|---|---|
B | 20 to 1820 | 150 to 1820 | 600 to 1820 |
E | –270 to 910 | –270 to 910 | –260 to 910 |
J | –210 to 1200 | –210 to 1200 | –210 to 1200 |
K | –270 to 1370 | –270 to 1370 | –250 to 1370 |
N | –270 to 1300 | –260 to 1300 | –230 to 1300 |
R | –50 to 1760 | –50 to 1760 | 20 to 1760 |
S | –50 to 1760 | –50 to 1760 | 20 to 1760 |
T | –270 to 400 | –270 to 400 | –250 to 400 |
USB TC-08 Manuals
Resource | Language | Version | Size | Updated |
---|---|---|---|---|
Data Sheets: | ||||
TC-08 Data Sheet | English | 9 | 3 MB | April 08 2019 |
User’s Guides: | ||||
TC-08 User’s Guide | English | 9 | 4 MB | May 20 2019 |
TC-08 Terminal Board User’s Guide | English | 1 | 99 KB | September 14 2009 |
Programmer’s Guides: | ||||
TC-08 Programmer’s Guide | English | 7 | 1 MB | September 20 2017 |
Quick Start Guides: | ||||
USB Data Logger Quick Start Guide | English |
8 | 1 MB | January 17 2012 |
Training Guides: | ||||
PicoLog Frequently Asked Questions | English | 3 | 932 KB | April 05 2019 |
Declarations: | ||||
TC-08 Data Logger EU Declaration of Conformity | English | 2 | 439 KB | December 07 2017 |
TC-08 Terminal Board EU Declaration of Conformity | English | 1 | 172 KB | November 22 2016 |
USB TC-08 Manuals
Resource | Language | Version | Size | Updated |
---|---|---|---|---|
Data Sheets: | ||||
TC-08 Data Sheet | English | 9 | 3 MB | April 08 2019 |
User’s Guides: | ||||
TC-08 User’s Guide | English | 9 | 4 MB | May 20 2019 |
TC-08 Terminal Board User’s Guide | English | 1 | 99 KB | September 14 2009 |
Programmer’s Guides: | ||||
TC-08 Programmer’s Guide | English | 7 | 1 MB | September 20 2017 |
Quick Start Guides: | ||||
USB Data Logger Quick Start Guide | English |
8 | 1 MB | January 17 2012 |
Training Guides: | ||||
PicoLog Frequently Asked Questions | English | 3 | 932 KB | April 05 2019 |
Declarations: | ||||
TC-08 Data Logger EU Declaration of Conformity | English | 2 | 439 KB | December 07 2017 |
TC-08 Terminal Board EU Declaration of Conformity | English | 1 | 172 KB | November 22 2016 |