The PicoLog CM3 Current Data Logger is a compact, easy-to-use data logger for measuring the current consumption of buildings and machinery.
Product Information
Now with PicoLog Cloud®
Building on the proven design of PicoLog 6, PicoLog Cloud is a free upgrade that introduces many great new features that expand how your Pico data logger can be used.
PicoLog Cloud allows all current Pico data loggers and real-time scopes to capture data directly to our new free Cloud service, and can be shared via a link to any browser on a PC, phone or tablet, anywhere in the world. In addition, an API can be used that allows live capture data to be transferred from the Cloud to a 3rd party database or program.
Three-channel data logger
The PicoLog CM3 is a three-channel data logger that uses industry-standard current clamps. Simply connect to your PC via USB or Ethernet, run the supplied software and you can monitor and log current for a wide range of applications.
- Suitable for single or three-phase alternating currents
- Non-invasive measurement
- High resolution and accuracy
- No power supply required
- USB and Ethernet interfaces
- Run multiple units on a single PC
Typical applications
- Mains current monitoring
- Three-phase load balancing
- Long-term energy use recording
- Energy and cost saving / ISO14001 monitoring
Flexible, expandable software included
Your PicoLog CM3 Current Data Logger is supplied with PicoLog 6 data logging software, available for Windows, macOS and Linux. With PicoLog 6 you can collect almost unlimited datasets, analyze them and then display the results in spreadsheet and graphical formats.
PicoLog 6 can record data from multiple PicoLog data loggers at the same time. This allows you to collect up to 60 channels of current. You can even mix and match different PicoLog loggers to record a mix of current, temperature, voltage and other signals.
The PicoSDK, a software development kit (SDK) is also supplied. PicoSDK contains a range of software drivers and example code that you can use to write your own software or to use your PicoLog CM3 with third-party software such as MATLAB, C,C++, C#, LabVIEW, Python, VB, VB.net to name but a few. PicoSDK can be found on GitHub.
Both PicoLog 6 and PicoSDK are provided free of charge and updates can be downloaded for free.
Non-invasive current clamps
The PicoLog CM3 measures current using industry-standard AC current clamps. These clamps have opening jaws so can be installed in seconds with no physical connection to high voltages. AC current clamps require no power supply or batteries so are ideal for long-term energy-use monitoring and logging.
Pico supply 200 A AC current clamps as standard. If you need to measure higher currents we will be happy to advise on suitable clamps for your application.
The PicoLog CM3 is available on its own so you can add your own current clamps or as a cost-saving kit with three 200 A clamps included.

USB or Ethernet connection for local or remote logging
With both USB and Ethernet interfaces your PicoLog CM3 can be used in a variety of situations. If you need a portable instrument that can be used at various locations and is fast to set up and use, simply connect your laptop to the PicoLog CM3 by USB. No external power supply is required as the CM3 is powered from the USB port.
Need to monitor a situation over a period of hours or days, or from a remote location? Plug your PicoLog CM3 into a spare port on your network and then access it remotely either from your LAN or over the internet. When using Ethernet the CM3 can be powered either by Power over Ethernet (PoE) or by using the USB connection just for power.
- Suitable for single or three-phase alternating currents
- Non-invasive measurement
- High resolution and accuracy
- No power supply required
- USB and Ethernet interfaces
- Run multiple units on a single PC
| PicoLog CM3 current data logger specifications | |
|---|---|
| Number of channels | 3 |
| Range (voltage input) | 0 to 1 V AC RMS |
| Accuracy (voltage input) < 200 mV RMS < 1 V RMS |
±1% ±2.5% |
| RMS noise | 60 µV |
| Resolution | 24 bit |
| Conversion time per enabled channel | 720 ms |
| Voltage input | 1 V RMS, 20 Hz to 1 kHz |
| Input connectors | 4 mm sockets |
| Input impedance | >1 MΩ, AC coupled |
| Overvoltage protection | ±30 V DC |
| PC requirements | |
|---|---|
| Minimum | Processor: 1 GHz Memory: 512 MiB Free disk space: 32-bit: 600 MB, 64-bit: 1.5 GB Operating system: 32- or 64-bit edition of Microsoft Windows XP (SP3), Vista, Windows 7, Windows 8.1 (not Windows RT) or Windows 10 Ports: USB 1.1 port or Ethernet. |
| Recommended | Processor: 1 GHz Memory: 512 MiB Free disk space: 32-bit: 850 MB, 64-bit: 2 GB Operating system: 32- or 64-bit edition of Microsoft Windows 7, Windows 8.1 (not Windows RT) or Windows 10 Ports: USB 1.1 (or higher), or Ethernet. |
| Environmental | |
|---|---|
| Operating environment Temperature range Humidity range |
0 °C to 50 °C (20 °C to 28 °C for stated accuracy) 20% to 80% RH, non-condensing |
| Storage environment Temperature range Humidity range |
–20 °C to +80 °C 5% to 95% RH, non-condensing |
| Physical properties | |
|---|---|
| Dimensions | 184 x 135 x 36 mm (approx 7.2 x 5.3 x 1.4 in) |
| Software | ||
|---|---|---|
| PicoLog for Windows | PicoLog data acquisition software can collect up to 1 million samples. Features include: Multiple views — view data as a graph, spreadsheet or text Parameter scaling — convert raw data into standard engineering units Math functions — use mathematical equations to calculate additional parameters Alarm limits — program an alert if a parameter goes out of a specified range IP networking — transfer measurements via a LAN or over the internet Operating systems supported — Microsoft Windows XP (SP3) to Windows 10. Not Windows RT. |
|
| PicoLog languages | Full support for — English, Français, Deutsch Menus and dialogs only for — Italiano, Español, Svenska |
|
| Software Development Kit | Includes example code. | |
| Optional free software | Drivers for Linux and OS X. | |
| Documentation languages | |
|---|---|
| User’s guide Programmer’s guide Installation guide |
English, Français, Deutsch, Italiano, Español, 中文 English English, Français, Deutsch, Italiano, Español, Svenska, Nederlandse, Dansk |
| General | |
|---|---|
| Additional hardware (supplied) | USB 2.0 cable, Ethernet cable, user manuals, software CD-ROM |
| PC interface | USB 2.0 (USB 1.1 compatible) or Ethernet |
| Power requirements | Powered from USB port or Ethernet |
| Compliance | European EMC and LVD standards FCC Rules Part 15 Class A RoHS compliant |
| Total satisfaction guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. |
| Warranty | 5 years |
Recommended Products
| Product | |||
|---|---|---|---|
| 200 A AC current clamp (4 mm) TA138 Recommended |
|||
Compatible Products
- Oscilloscope accessories
- USB cables
Accessories
Accelerometers Probe positioning Oscilloscope training & demo board Calibration Test leads, adaptors and clips USB cables Storage and rackmount
| Product | |||
|---|---|---|---|
| USB Type-C to Standard-A (f) adaptor, 0.14 m TA285 |
|||
For more information, please click here
| Resource | Language | Version | Size | Updated |
|---|---|---|---|---|
| Data Sheets: | ||||
| PicoLog CM3 Data Sheet | English | 9 | 6 MB | September 13 2021 |
| Scheda tecnica PicoLog CM3 | Italiano | 9 | 2 MB | December 20 2021 |
| Fiche Technique PicoLog CM3 | Français | 9 | 2 MB | December 20 2021 |
| Ficha Técnica PicoLog CM3 | Español | 9 | 1 MB | December 20 2021 |
| Datenblatt PicoLog CM3 | Deutsch | 9 | 1 MB | December 20 2021 |
| PicoLog CM3 数据表 | 中文 (简体) | 9 | 2 MB | December 20 2021 |
| PicoLog CM3 データシート | 日本語 | 9 | 2 MB | December 20 2021 |
| PicoLog CM3 데이터 시트를 | 한국어 | 9 | 2 MB | December 20 2020 |
| User’s Guides: | ||||
| PicoLog CM3 User’s Guide | English | 5 | 3 MB | May 20 2019 |
| PicoLog CM3 Registrador de datos de corriente Guía del usuario | Español | 2 | 1 MB | August 02 2011 |
| PicoLog CM3 Strom-Datenaufzeichnungsgerät Benutzerhandbuch | Deutsch | 2 | 1 MB | August 02 2011 |
| PicoLog CM3 Enregistreur de données de courant manuel d’utilisation | Français | 2 | 1 MB | August 02 2011 |
| PicoLog CM3 Guida all’uso | Italiano | 2 | 1 MB | August 02 2011 |
| PicoLog CM3 电流数据记录器用户指南 | 中文 (简体) | 2 | 3 MB | August 02 2011 |
| Programmer’s Guides: | ||||
| PicoLog CM3 Current Data Logger Programmer’s Guide | English | 4 | 600 KB | November 19 2019 |
| Quick Start Guides: | ||||
| USB Data Logger Quick Start Guide | English Français Deutsch Italiano Español 中文 (简体) 한국어 日本語 |
10 | 2 MB | August 01 2022 |
| Training Guides: | ||||
| PicoLog Frequently Asked Questions | English | 3 | 938 KB | April 05 2019 |
| Declarations: | ||||
| PicoLog CM3 EU Declaration of Conformity | English | 2 | 417 KB | November 01 2018 |