The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over other digital multimeters available on the market, including Fluke model 7-600. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. LoZ low impedance measurements also block ghost voltages induced by nearby conductors. *Be advised that LoZ low impedance measurements present a low load to a circuit protected by an RCD, which can cause the RCD to trip. The Min/Max function lets you record signal fluctuations. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
Specifications
VCHEK1 2 3
Range
6.000 V / 60.00 V / 600.0 V
Resolution
0.001 V / 0.01 V/ 0.1 V
Accuracy
DC, 45 to 500 Hz: 2.0% + 3 500 Hz to 1 kHz: 4.0% + 3
Diode test4
2.000 V
0.001 V
2.0% + 3
Continuity4
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
Ω4
600.0 Ω / 6.000 kΩ / 60.00 kΩ
0.1 Ω / 0.001 kΩ / 0.01 kΩ
0.9% + 2 / 0.9% + 1 / 0.9% + 1
Capacitance4
1000 nF / 10.00 μF / 100.0 μF / 9999 μF
1 nF / 0.01 μF / 0.1 μF / 1 μF
1.9% + 2 100 μF - 1000 μF: 1.9% + 2 1000 μF: 5% + 20
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range. 4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
Maximum voltage between any terminal and earth ground
600 V
Display
3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature
-10°C to 50°C (14°F to 122°F)
Storage temperature
-40°C to 60°C (-22°F to 140°F)
Temperature coefficient
0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating altitude
2,000 m
Storage altitude
10,000 m
Relative humidity
95% to 30°C 75% to 40°C 45% to 50°C
Battery type
9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery life
Alkaline: 300 hours typical, without backlight
Shock
1 Meter drop per IEC 61010–1–2001
Vibration
Per MIL-PRF-28800 for Class 2 instrument
Size (H x W x L)
167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
Weight
13.0 oz (404 g)
Safety
Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1
EMI regulations
Complies with FCC Part 15, Class B
VCHEK
Input impedance (nominal)
~3 kΩ < 300 pF
Common mode rejection ratio (1 kΩ unbalanced)
> 60 dB at DC, 50 or 60 Hz
Ω
Open circuit test voltage
< 2.7 VDC
Full scale voltage
< 0.7 VDC
Diode test
2.7 VDC
2.000 VDC
Short circuit current
< 350 μA
< 1.0 mA
Includes
Holster
Users manual
and 9 V battery (installed)