The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment
The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.
Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.
Other useful features:
Key features
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to + 50°C
Storage temperature
-40°C to + 60°C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
±([% of reading] + [counts]): 0.5% + 2
DC volts
6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
Auto volts
600.0 V / 0.1 V
2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
Continuity
600 Ω / 1 Ω
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
0.9% + 1
Range/Resolution
40.00 MΩ / 0.01 MΩ
5% + 2
Diode Test
2.00 V / 0.001 V
0.9% + 2
Capacitance
1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
1.9% + 2
> 1000 μF
5% + 20%
Lo-Z Capacitance
Range
1 nF to 500 μF
10% + 2 typical
Temperature² (Type-K thermocouple)
-40°C to 400°C / 0.1°C
1% + 10²
-40°F to 752°F / 0.2°F
1% + 18²
AC μA true-rms (45 Hz to 500 Hz)
600.0 μA / 0.1 μA
1.5% + 3
DC μamps
1.0% + 2
Hz (V or A input)²
99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz
0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight
550 g
Warranty
3 years
Includes:
For more information, click here.
Manuals
Data Sheets
Selection Guide