Personal Greeting

Performance and functionality for debugging next-generation embedded systems

The PicoScope 6000E Series fixed-resolution and FlexRes oscilloscopes provide 8 to 12 bits of vertical resolution, with 500 MHz bandwidth and 5 GS/s sampling rate. Eight analog channels have the timing and amplitude resolution you need to reveal signal integrity issues such as glitches, runts, dropouts, noise, distortion and ringing. 16 digital MSO channels enable the debug and verification of complex ECUs and FPGA-based designs.

  • 8-bit to 12-bit FlexRes® ADCs
  • 8 x 500 MHz analog channels
  • Up to 16 x 1 Gb/s digital channels
  • Dual 5 GS/s ADCs
  • 4 GS capture memory (up to 2 GS per trace)
  • 50 MHz 200 MS/s 14-bit AWG
  • 300 000 waveforms per second update rate
  • Free PicoScope 6 and PicoSDK software
  • Serial decoding and mask limit testing
  • High-resolution timestamping of waveforms
  • Over ten million DeepMeasure™ results per acquisition
  • Advanced triggers: pulse width, runt pulse, windowed, logic and dropout

Typical applications

These oscilloscopes, with PicoScope 6 application software, are ideal for design engineers working with high-performance embedded systems, signal processing, power electronics, mechatronics and automotive designs, and for researchers and scientists working on multichannel high-performance experiments in physics labs, particle accelerators and similar facilities.

The PicoScope 6000E Application Programming Interface (API) provides programming access to the full set of advanced hardware features and can be used to develop diverse custom and OEM applications. 

Best-in-class bandwidth, sampling rate and memory depth

With 500 MHz analog bandwidth complemented by a real-time sampling rate of 5 GS/s, the PicoScope 6000E Series scopes can display single-shot pulses with 200 ps time resolution.

The PicoScope 6000E Series gives you the deepest capture memory—up to 4 GS in total—available as standard on any oscilloscope at any price. This ultra-deep memory allows the oscilloscope to capture 200 ms waveforms at its maximum sampling rate of 5 GS/s.

The SuperSpeed USB 3.0 interface and hardware acceleration ensure that the display is smooth and responsive even with long captures.

The PicoScope 6000E Series gives you the waveform memory, resolution and analysis tools that you need to perform stringent testing of high-performance electronics devices and next-generation embedded system designs.

Power, portability and performance

Conventional eight-channel benchtop mixed-signal oscilloscopes occupy too much space on the bench and are too costly for most engineers working on next-generation designs. PicoScope 6000E Series oscilloscopes are small and portable, while offering the high-performance specifications required by engineers in the lab or on the move.

These oscilloscopes offer 8 analog channels, plus an optional 8 or 16 digital channels with the plug-in 8-channel TA369 MSO pods. The flexible high‑resolution display options enable you to view and analyze each signal in detail.

Supported by the PicoScope 6 software, these devices offer an ideal, cost-effective package for many applications, including design, research, test, education, service, and repair. PicoScope 6 is included in the cost of your scope, available for free download, with free updates, and can be installed on as many PCs as you want, including to view/analyze data off-line without the scope

High-end features as standard

Buying a PicoScope is not like making a purchase from other oscilloscope companies, where optional extras considerably increase the price. With our scopes, high-end features such as serial decoding, mask limit testing, advanced math channels, segmented memory, hardware-based timestamping and a signal generator are all included in the price.

To protect your investment, both the PC software and firmware inside the scope can be updated. Pico Technology has a long history of providing new features for free through software downloads. We deliver on our promises of future enhancements year after year. Users of our products reward us by becoming lifelong customers and frequently recommending us to their colleagues.

Powerful tools provide endless options

Your PicoScope is provided with many powerful tools to help you acquire and analyze waveforms. While these tools can be used on their own, the real power of PicoScope lies in the way they have been designed to work together.

As an example, the rapid trigger mode allows you to collect 10 000 waveforms in a few milliseconds with minimal dead time between them. Manually searching through these waveforms would be time-consuming, so just pick a waveform you are happy with and let the mask tools scan through for you. When done, the measurements will tell you how many have failed and the buffer navigator allows you to hide the good waveforms and just display the problem ones.

The screenshot here shows changing frequency versus time as a graph. Perhaps instead you want to plot changing duty cycle as a graph? How about outputting a waveform from the AWG and also automatically saving the waveform to disk when a trigger condition is met? With the power of PicoScope the possibilities are endless. To find out more about the capabilities of PicoScope software, visit our A to Z of PC Oscilloscopes.

PicoScope 6000E Series with ultra-deep capture memory

With 500 MHz analog bandwidth complemented by a real-time sampling rate of 5 GS/s, the PicoScope 6000E Series scopes can display single-shot pulses with 200 ps time resolution.

The PicoScope 6000E Series gives you the deepest capture memory—up to 4 GS in total—available as standard on any oscilloscope at any price. This ultra-deep memory allows the oscilloscope to capture 200 ms waveforms at its maximum sampling rate of 5 GS/s.

The SuperSpeed USB 3.0 interface and hardware acceleration ensure that the display is smooth and responsive even with long captures.

The PicoScope 6000E Series gives you the waveform memory, resolution and analysis tools that you need to perform stringent testing of today’s high‑performance embedded computers and next-generation embedded system designs.

 

Signal fidelity

Careful front-end design and shielding reduce noise, crosstalk and harmonic distortion. PicoScope 6000E Series oscilloscopes exhibit a dynamic performance of up to 60 dB SFDR.

With PicoScope 6, when you probe a circuit, you can trust in the waveform you see on the screen.

 

..

 

Deep capture memory

With 500 MHz analog bandwidth complemented by a real-time sampling rate of 5 GS/s, the PicoScope 6000E Series scopes can display single-shot pulses with 200 ps time resolution.

The PicoScope 6000E Series gives you the deepest capture memory—up to 4 GS in total—available as standard on any oscilloscope at any price. This ultra-deep memory allows the oscilloscope to capture a 200 ms waveform at its maximum sampling rate of 5 GS/s.

The SuperSpeed USB 3.0 interface and hardware acceleration ensure that the display is smooth and responsive even with long captures.

The PicoScope 6000E Series gives you the waveform memory, resolution and analysis tools that you need to perform stringent testing of today’s high‑performance embedded computers and next-generation embedded system designs.

More information on deep-memory oscilloscopes >>

 

What is FlexRes?

Pico FlexRes flexible-resolution oscilloscopes allow you to reconfigure the scope hardware to optimize either the sampling rate or the resolution.

This means you can reconfigure the hardware to be either a fast (5 GS/s) 8-bit oscilloscope for looking at digital signals or a high-resolution 12-bit oscilloscope for audio work and other analog applications.

Whether you’re capturing and decoding fast digital signals or looking for distortion in sensitive analog signals, FlexRes oscilloscopes are the answer.

FlexRes is available on the PicoScope 6824E.

Resolution enhancement—a digital signal processing technique built into PicoScope 6— can further increase the effective vertical resolution of the scope to 16 bits.

More information on flexible resolution >>

 

FlexRes - how we do it

Most digital oscilloscopes gain their high sampling rates by interleaving multiple 8-bit ADCs. This interleaving process introduces errors that always make the dynamic performance worse than that of the individual ADC cores.

The FlexRes architecture employs multiple high-resolution ADCs at the input channels in different time-interleaved and parallel combinations to optimize either the sampling rate to 5 GS/s at 8 bits, the resolution to 12 bits at 1.25 GS/s, or other combinations in between.

The diagram shows one bank of four channels; the PicoScope 6824E has two banks.

Coupled with high signal-to-noise ratio amplifiers and a low-noise system architecture, FlexRes technology can capture and display signals up to 500 MHz with a high sampling rate, or lower-speed signals with 16 times more resolution than typical 8-bit oscilloscopes.

The PicoScope 6 software lets you choose between setting the resolution manually and leaving the scope in auto resolution mode, where the optimal resolution is used for the chosen settings.

 

Mixed-signal options

Most benchtop mixed-signal oscilloscopes give you a maximum of four analog channels and 16 digital inputs. When fitted with the optional 8-channel TA369 MSO pods, the PicoScope 6000E Series adds up to 16 high-performance digital channels to its eight analog channels, enabling you to accurately time-correlate analog and digital channels. Digital channel bandwidth is 500 MHz, equivalent to 1 Gb/s, and the input capacitance of only 3.5 pF minimizes loading on the device under test.

Digital channels, captured from either parallel or multiple serial buses, may be grouped and displayed as a bus, with each bus value displayed in hex, binary or decimal, or as a level (for DAC testing). You can set advanced triggers across the analog and digital channels.

The digital inputs also bring extra power to the serial decoding feature. You can decode serial data on all analog and digital channels simultaneously, giving you up to 24 channels of data – for example, decoding multiple SPI, I²C, CAN bus, LIN bus and FlexRay signals all at the same time!

More information on mixed-signal oscilloscopes >>

 

High resolution for low-level signals

With its 12-bit resolution, the PicoScope 6824E can display low-level signals at high zoom factors. This allows you to view and measure features such as noise and ripple superimposed on larger DC or low-frequency voltages.

Additionally, you can use the lowpass filtering controls on each channel independently, to hide noise and reveal the underlying signal.

 

Arbitrary waveform and function generator

The PicoScope 6000E scopes have a built-in 50 MHz function (sine and square wave) generator, with triangle, DC level, white noise, PRBS and other waveforms possible at lower frequencies. As well as basic controls to set level, offset and frequency, more advanced controls allow you to sweep over a range of frequencies. Combined with the spectrum peakhold option, this makes a powerful tool for testing amplifier and filter responses.

Trigger tools allow one or more cycles of a waveform to be output when various conditions are met, such as the scope triggering or a mask limit test failing.

Both models include a 14-bit 200 MS/s arbitrary waveform generator (AWG). This has a variable sample clock, which avoids jitter on waveform edges seen with fixed-clock generators and allows generation of accurate frequencies down to 100 µHz. AWG waveforms can be created or edited using the built-in editor, imported from oscilloscope traces, loaded from a spreadsheet or exported to a .csv file.

More information on the arbitrary waveform and function generator >>

 

Digital triggering architecture

Many digital oscilloscopes still use an analog trigger architecture based on comparators. This causes time and amplitude errors that cannot always be calibrated out and often limits the trigger sensitivity at high bandwidths.

In 1991 Pico pioneered the use of fully digital triggering using the actual digitized data. This technique reduces trigger errors and allows our oscilloscopes to trigger on the smallest signals, even at the full bandwidth. Trigger levels and hysteresis can be set with high precision and resolution.

Advanced triggers

The PicoScope 6000E Series offers an industry-leading set of advanced trigger types including pulse width, runt pulse, windowed, logic and dropout.

The digital trigger available during MSO operation allows you to trigger the scope when any or all of the 16 digital inputs match a user-defined pattern. You can specify a condition for each channel individually, or set up a pattern for all channels at once using a hexadecimal or binary value.

You can also use the logic trigger to combine the digital trigger with an edge or window trigger on any of the analog inputs, for example to trigger on data values in a clocked parallel bus.

More information on advanced digital triggers >>

 

Hardware acceleration engine HAL4

Some oscilloscopes struggle when you enable deep memory; the screen update rate slows and the controls become unresponsive. The PicoScope 6000E Series avoids this limitation with the use of a dedicated fourth-generation hardware acceleration (HAL4) engine inside the oscilloscope.

Its massively parallel design effectively creates the waveform image to be displayed on the PC screen and allows the continuous capture and display to the screen of 2.5 billion samples every second.

The hardware acceleration engine eliminates any concerns about the USB connection or PC processor performance being a bottleneck.

 

Timestamping

The PicoScope 6000E Series features hardware-based trigger timestamping.

Each waveform can be time-stamped with the time in sample intervals from the previous waveform.

Fast trigger rearm times are possible down to 300 ns (typical).

 
 

.Intelligent probe interface (probes coming soon!)

With an intelligent probe interface on channels C to F, the PicoScope 6000E Series will support innovative active probes with a low-profile mechanical design for ease of connectivity and low loading of the device under test.

PicoScope 6000E Series specifications

Vertical (analog channels) PicoScope 6804E PicoScope 6824E
Input channels 8
Bandwidth (–3dB) 500 MHz
Rise time < 850 ps
Bandwidth limit 20 MHz, selectable
Vertical resolution 8 bits fixed 8, 10 or 12 bits FlexRes
Enhanced vertical resolution (software) Up to 4 extra bits beyond ADC resolution
Input type Single-ended BNC connector
Input characteristics 1 MΩ ±0.5% in parallel with 12 pF ±1 pF, or 50 Ω ±2%
Input coupling 1 MΩ AC/DC or 50 Ω DC
Input sensitivity 2 mV/div to 4 V/div (10 vertical divisions)
Input ranges (full scale) 1 MΩ ranges: ±10 mV, ±20 mV, ±50 mV, ±100 mV, ±200 mV, ±500 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V
50 Ω ranges: ±10 mV, then as above up to ±5 V
DC gain accuracy ±(1.5% of signal + 1 LSB) ±(0.5% of signal + 1 LSB)
DC offset accuracy ±(1% of full scale + 250 µV). Offset accuracy can be improved by using the “zero offset” function in PicoScope 6.
LSB size (quantization step size) 8 bits: < 0.4 % of input range 8 bits: < 0.4 % of input range
10 bits: < 0.1 % of input range
12 bits: < 0.025 % of input range
Analog offset range (vertical position adjustment) ±1.25 V (10 mV to 1 V ranges)
±20 V (2 V to 20 V ranges)
Analog offset control accuracy ±0.5% of offset setting, additional to DC accuracy above
Overvoltage protection 1 MΩ ranges: ±100 V (DC + AC peak) up to 10 kHz
50 Ω ranges: 5.5 V RMS
Vertical (digital channels with optional TA369 8-channel MSO pods)
Input channels Up to 16 channels (2 ports of 8 channels)
Maximum detectable input frequency 500 MHz (1 Gb/s)
Minimum detectable pulse width 1 ns
Input connector (probe tip) Staggered signal and ground pin sockets for each channel, to accept 0.64 to 0.89 mm round or 0.64 mm square pin, 2.54 mm pitch
Input impedance 101 kΩ ±1% in parallel with 3.5 pF ±0.5 pF
Threshold range and resolution ±8 V in 5 mV steps
Threshold accuracy ±(100 mV + 3% of threshold setting)
Threshold grouping PicoScope 6: Two independent threshold controls, one per 8-channel port
PicoSDK: Individual threshold for each channel
Threshold selection TTL, CMOS, ECL, PECL, user-defined
Maximum input voltage at probe tip ±40 V up to 10 MHz, derated linearly to ±5 V at 500 MHz
Minimum input voltage swing (at 500 MHz) 400 mV peak to peak
Hysteresis (at DC) PicoScope 6: Fixed hysteresis approx. 100 mV.
Using PicoSDK, selectable hysteresis per port:
Low: approx 50 mV
Normal: approx 100 mV
High: approx 200 mV
Very high: approx 400 mV
Minimum input slew rate No minimum slew rate requirement
Horizontal PicoScope 6804E PicoScope 6824E
Maximum sampling rate (real time, 8-bit mode) Up to 2 total analog channels and/or digital ports: 5 GS/s (one from channels ABCD, the other from channels EFGH).
Up to 4 total analog channels and/or digital ports: 2.5 GS/s (one from channels AB, one from CD, one from EF and one from GH).
Up to 8 total analog channels and/or digital ports: 1.25 GS/s.
All other combinations: 625 MS/s.
Maximum sampling rate (real time, 10-bit mode) N/A 1 analog channel or digital port: 5 GS/s.
Up to 2 total analog channels and/or digital ports: 2.5 GS/s (not applicable with the following channel combinations: AB, CD, EF, GH).
Up to 4 total analog channels and/or digital ports: 1.25 GS/s.
Up to 8 total analog channels and/or digital ports: 625 MS/s.
All other combinations: 312.5 MS/s.
Maximum sampling rate (real time, 12-bit mode) N/A 1.25 GS when using one channel from ABCD and/or one channel from EFGH, plus any digital ports.
Max. sampling rate, USB streaming mode, PicoScope 6 ~20 MS/s on USB 3.0
Split between active channels, PC-dependent
Max. sampling rate, USB streaming mode, PicoSDK ~312 MS/s on USB 3.0 ~312 MS/s on USB 3.0 (8-bit mode)
~156 MS/s on USB 3.0 (10/12-bit modes)
Split between active channels, PC-dependent.
Capture memory (shared between active channels) 2 GS 4 GS (2 GS at 10/12-bit).
Max. single capture in PicoScope 6: 2 GS.
Max. single capture with PicoSDK: 4 GS.
Capture memory (continuous streaming) 100 MS in PicoScope software. Buffering using full device memory when using PicoSDK, no limit on total duration of capture.
Waveform buffer (number of segments) PicoScope 6: 10 000; PicoSDK: 2 000 000
Timebase ranges 1 ns/div to 5000 s/div
Initial timebase accuracy ±2 ppm
Timebase drift ±1 ppm/year
ADC sampling Simultaneous sampling on all enabled analog and digital channels
External reference clock
Input characteristics High-Z, AC coupled (> 1 kΩ at 10 MHz)
Input frequency range 10 MHz ±50 ppm
Input connector Rear panel BNC, dedicated
Input level 200 mV to 3.3 V peak to peak
Overvoltage protection ±5 V peak max
Dynamic performance (typical) PicoScope 6804E PicoScope 6824E
Crosstalk ±10 mV to ±1 V ranges: better than 1200:1 up to full bandwidth (equal voltage ranges)
±2 V to ±20 V ranges: better than 300:1 up to full bandwidth (equal voltage ranges)
Harmonic distortion, 8-bit mode –50 dB at 1 MHz full scale
Harmonic distortion, 10/12-bit mode N/A –60 dB at 1 MHz full scale
SFDR, 8-bit mode > 50 dB on ±50 mV to ±20 V ranges
SFDR, 10/12-bit mode N/A > 60 dB on ±50 mV to ±20 V ranges
Noise, 8-bit mode < 200 μV RMS on most sensitive range
Noise, 10/12-bit mode N/A < 150 μV RMS on most sensitive range
Linearity, 8-bit mode < 2 LSB
Linearity, 10-bit mode N/A < 4 LSB
Bandwidth flatness (+0.3 dB, –3 dB) from DC to full bandwidth
Low frequency flatness < ±3% (or ±0.3 dB) from DC to 1 MHz
Triggering
Source Any analog channel, AUX trigger, plus digital ports with optional TA369 MSO pod
Trigger modes None, auto, repeat, single, rapid (segmented memory)
Advanced trigger types (analog channels) Edge, window, pulse width, window pulse width, dropout, window dropout, interval, runt, logic
Logic allows arbitrary combinations of up to 4 analog channels or MSO ports
Trigger sensitivity (analog channels) Digital triggering provides 1 LSB accuracy up to full bandwidth of scope
Trigger types (digital inputs) With optional MSO pods: Edge, pulse width, dropout, interval, logic, pattern, mixed signal
Maximum pre-trigger capture 100% of capture size
Maximum post trigger delay PicoScope 6: up to 0.8 s at fastest timebase
PicoSDK: > 1012 samples, settable in 1 sample steps (delay range at fastest sample rate of > 200 s in 200 ps steps)
Rapid trigger mode rearm time 700 ns max, 300 ns typical (single channel, 5 GS/s)
Maximum trigger rate PicoScope 6: 10 000 waveforms in 3 ms
PicoSDK: 2 million waveforms in 0.6 s
Trigger time-stamping Single sample-interval resolution, relative to previous waveform. Resets when any settings are changed.
Auxiliary trigger I/O
Connector type Rear-panel BNC
Trigger types (triggering scope) Edge, pulse width, dropout, interval, logic
Input bandwidth > 10 MHz
Input characteristics 2.5 V CMOS high-Z input
Threshold range Fixed threshold, 1.25 V nominal
Hysteresis 1 V max (VIH < 1.75V, VIL > 0.75V)
Coupling DC
Overvoltage protection ±20 V peak max
Function generator
Standard output signals Sine, square, triangle, DC voltage, ramp up, ramp down, sinc, Gaussian, half-sine
Standard signal frequency Sine: 100 μHz to 50 MHz
Square: 100 μHz to 50 MHz
Other waves: 100 μHz to 1 MHz
Output frequency accuracy Oscilloscope timebase accuracy ± output frequency resolution
Output frequency resolution 0.002 ppm
Sweep modes Up, down, dual with selectable start/stop frequencies and increments
Sweep frequency range Sine / square waves: 0.075 Hz to 50 MHz
Other waves: 0.075 Hz to 1 MHz
Swept frequencies down to 100 μHz are possible via PicoSDK with some restrictions
Sweep frequency resolution In PicoScope 6 software: 0.075 Hz
Sweep frequency resolution down to 100 μHz is possible via PicoSDK with some restrictions
Triggering Free-run, or from 1 to 1 billion counted waveform cycles or frequency sweeps. Triggered from scope trigger or manually.
Gating Software-controlled gating of waveform output
Pseudorandom output signals White noise, selectable amplitude and offset within output voltage range
Pseudorandom binary sequence (PRBS), selectable high and low levels within output voltage range, selectable bit rate up to 50 Mb/s
Output voltage range ±5 V into open circuit; ±2.5 V into 50 Ω
Output voltage adjustment Signal amplitude and offset adjustable in < 1 mV steps within overall range
DC accuracy ±(0.5% of output voltage + 20 mV)
Amplitude flatness < 2.0 dB to 50 MHz (sine wave into 50 Ω)
< 0.5 dB to 50 MHz (square)
< 1.0 dB to 1 MHz (other waveforms)
Analog filters 50 MHz selectable filter (5-pole, 30 dB/octave)
SFDR 70 dB (10 kHz 1 V peak to peak sine into 50 Ω)
Output noise < 700 μV RMS (DC output, filter enabled, into 50 Ω load)
Output resistance 50 Ω ±3%
Connector type Rear panel BNC
Overvoltage protection ±20 V peak max
Arbitrary waveform generator
Update rate Variable from < 1 S/s to 200 MS/s with < 0.02 ppm resolution
Buffer size 40 kS
Vertical resolution 14 bits (output step size < 1 mV)
Bandwidth No filter: 100 MHz
Filtered: 50 MHz
Rise time (10% to 90%) No filter: 3.5 ns
Filtered: 6 ns
Sweep modes, triggering, frequency accuracy and resolution, voltage range and accuracy and output characteristics as for function generator.
Probe support
Active probe interface Active probe interface on four channels supporting A6000 Series active probes. Probe interface supplies power and controls the active probe.
Probe detection Automatic detection of P2056 10:1 oscilloscope probe
Probe compensation pin 1 kHz, 2 V peak to peak square wave, 600 Ω
Probe compensation pin rise time < 50 ns
Spectrum analyzer
Frequency range DC to 500 MHz
Display modes Magnitude, average, peak hold
Y axis Logarithmic (dbV, dBu, dBm, arbitrary dB) or linear (volts)
X axis Linear or logarithmic
Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman−Harris, Hamming, Hann, flat-top
Number of FFT points Selectable from 128 to 1 million in powers of 2
Math channels
Functions −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, delay, average, frequency, derivative, integral, min, max, peak, duty, highpass, lowpass, bandpass, bandstop
Operands A to H (input channels), T (time), reference waveforms, pi, 1D0 to 2D7 (digital channels), constants
Automatic measurements
Scope mode AC RMS, true RMS, frequency, cycle time, duty cycle, DC average, falling rate, rising rate, low pulse width, high pulse width, fall time, rise time, minimum, maximum, peak to peak
Spectrum mode Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD
Statistics Minimum, maximum, average, standard deviation
DeepMeasure™
Parameters Cycle number, cycle time, frequency, low pulse width, high pulse width, duty cycle (high), duty cycle (low), rise time, fall time, undershoot, overshoot, max. voltage, min. voltage, voltage peak to peak, start time, end time
Serial decoding
Protocols 1-Wire, ARINC 429, BroadR-Reach, CAN & CAN FD, DALI, DCC, DMX512, Ethernet 10Base-T and 100Base-TX, FlexRay, I²C, I²S, LIN, PS/2, Manchester, Modbus, SENT, SPI, UART (RS-232 / RS-422 / RS-485), and USB 1.1
Mask limit testing
Statistics Pass/fail, failure count, total count
Mask creation User-drawn, table entry, auto-generated from waveform or imported from file
Display
Interpolation Linear or sin(x)/x
Persistence modes Digital color, analog intensity, custom, fast
Languages Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish
General specifications
Package contents PicoScope 6000E Series 8-channel oscilloscope
Quick Start Guide
Power supply, universal input
USB 3.0 cable
Carry case
PC connectivity USB 3.0 SuperSpeed (USB 2.0 compatible)
PC connector type USB Type B
Power requirement 12 V DC from supplied PS016 PSU. Up to 7 A including powered accessories.
Ground terminal Functional ground terminal accepting wire or 4 mm plug, rear panel
Dimensions 245 x 192 x 61.5 mm
MSO digital interface cable length 500 mm (scope to pod)
MSO probe flying lead length 225 mm (pod to probe tip)
MSO pod size 75 x 55 x 18.2 mm
MSO probe size 34.5 x 2.5 x 6.7 mm (including ground pin)
Weight 2.2 kg (scope only) 5.6 kg (in carry case with PSU and cables)
Temperature range Operating: 0 to 40 °C
For quoted accuracy after 20 minutes warm-up: 15 to 30 °C
Storage: –20 to +60 °C
Humidity range Operating: 5% to 80% RH non-condensing
Storage: 5% to 95% RH non-condensing
Altitude range Up to 2000 m
Pollution degree EN 61010 pollution degree 2: “only nonconductive pollution occurs except that occasionally a temporary conductivity caused by condensation is expected”
IP rating IP20
Safety compliance Designed to EN 61010-1:2010
EMC compliance Tested to EN 61326-1:2013 and FCC Part 15 Subpart B
Environmental compliance RoHS & WEEE compliance
Software PicoScope 6: All supported Windows operating systems. Beta software also available for 64-bit Linux and macOS.
PicoSDK: All supported Windows operating systems. Drivers also available for 64-bit Linux and macOS.
Users writing their own apps can find example programs for all platforms on the Pico Technology organization page on GitHub.
PC requirements Processor, memory and disk space: as required by the operating system
Ports: USB 3.0 (recommended) or 2.0 (compatible)
Warranty 5 years

Standard passive probes

Our ergonomically designed passive oscilloscope probes are suitable for use with all major brands of oscilloscopes as well as the PicoScope range of USB Oscilloscopes. Passive probes don't require a power supply or batteries so are lightweight and easily portable.

Read our free guide: How to Tune x10 Oscilloscope Probes.

Passive probe accessories

Our ergonomically designed passive oscilloscope probes are suitable for use with all major brands of oscilloscopes as well as the PicoScope range of USB Oscilloscopes. Passive probes don't require a power supply or batteries so are lightweight and easily portable.

Read our free guide: How to Tune x10 Oscilloscope Probes.

 

For more information, click here.

PicoScope 6000E Series documentation

Resource Language Version Size Updated
Data Sheets:
PicoScope 6000E Series Data Sheet English 1 18 MB February 11 2020
User’s Guides:
TA369 8-channel MSO Pod User’s Guide English 1 2 MB February 07 2020
PicoScope 6 User’s Guide English 50 10 MB February 24 2020
Quick Start Guides:
PicoScope 6000E Series Quick Start Guide English
Français
Deutsch
Italiano
Español
中文 (简体)
한국어
日本語
1 8 MB February 13 2020
Declarations:
PicoScope 6000E EU Declaration of Conformity English 1 2 MB February 19 2020