Now it’s easy to increase your IR temperature measurement accuracy with the new Fluke Calibration  4180, 4181 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

  • Calibrated radiometrically for meaningful, consistent results.
  • Accredited calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large target size of 152 mm (6 in) is required for calibrating most thermometers.
  • Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
  • Intuitive, easy-to-read display that indicates when temperature is stable.

The 4180 Series of Precision InfraredCalibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. It comes with an accredited calibration from one of the world’s most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making high-quality infrared thermometer calibrations. This is the perfect solution for any infrared thermometer or thermal imager within its temperature range.

The 4180 Infrared Temperature Calibrator reaches temperatures from –15 °C to 120 °C and the 4181 Infrared Temperature Calibrator has a temperature range from 35 °C to 500 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.

In addition, with accuracies as good as ± 0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.

Emissivity, blackbodies and graybodies
Most people associate a blackbody calibration source with calibrating infrared thermometers. Although the word blackbody specifically refers to an ideal surface that emits and absorbs electromagnetic radiation with the maximum amount of power possible at a given temperature, many calibrators with non-ideal surfaces are also referred to as "blackbody calibrators." While an ideal surface would have an emissivity equal to 1.00, many of these "blackbody calibrators" have an emissivity of approximately 0.95 (better described as a “graybody”). A true blackbody calibration source would usually be a long cavity with a narrow opening. Unfortunately the opening is usually too narrow to be useful for calibrating common infrared thermometers which require a large target size for an accurate calibration. The advantage of a true blackbody calibration source is that the emissivity is precisely known. Whereas traditional flat plate calibrators have emissivities with uncertainties too large for meaningful calibrations of most thermometers. That is why the 418X Precision Infrared Thermometers are radiometrically calibrated to correct for uncertainties caused by emissivity and heat loss at the surface of the "blackbody" calibration source.

Specifications
Temperature range (@ 23 °C ambient, 0.95 emissivity)
4180  –15 °C to 120 °C
4181  35 °C to 500 °C
Display accuracy1
4180  ± 0.40 °C at –15 °C
   ± 0.40 °C at 0 °C
   ± 0.50 °C at 50 °C
   ± 0.50 °C at 100 °C
   ± 0.55 °C at 120 °C
4181  ± 0.35 °C at 35 °C
   ± 0.50 °C at 100 °C
   ± 0.70 °C at 200 °C
   ± 1.20 °C at 350 °C
   ± 1.60 °C at 500 °C
Stability
4180  ± 0.10 °C at –15 °C
   ± 0.05 °C at 0 °C
   ± 0.10 °C at 120 °C
4181  ± 0.05 °C at 35 °C
   ± 0.20 °C at 200 °C
   ± 0.40 °C at 500 °C
Uniformity (5.0 in dia of center of target)2
4180  ± 0.15 °C at –15 °C
   ± 0.10 °C at 0 °C
   ± 0.25 °C at 120 °C
4181  ± 0.10 °C at 35 °C
   ± 0.50 °C at 200 °C
   ± 1.00 °C at 500 °C
Uniformity (2.0 in dia of center of target)2
4180  ± 0.10 °C at -15 °C
   ± 0.10 °C at 0 °C
   ± 0.20 °C at 120 °C
4181  ± 0.10 °C at 35 °C
   ± 0.25 °C at 200 °C
   ± 0.50 °C at 500 °C
Heating time
4180  15 min: –15 °C to 120 °C
   14 min: 23 °C to 120 °C
4181  45 min: 35 °C to 500 °C
Cooling time
4180  15 min: 120 °C to 23 °C
   20 min: 23 °C to –15 °C
4181  100 min: 500 °C to 35 °C
   40 min: 500 °C to 100 °C
Stabilization time
   10 minutes
Nominal emissivity3
   0.95
Thermometer emissivity compensation
   0.9 to 1.0
Target diameter
   152.4 mm (6 in)
Computer interface
   RS-232
Power
4180  115 V ac (± 10%), 6.3 A,
   50/60 Hz, 630 W
   230 V ac (± 10%), 3.15 A,
   50/60 Hz, 630 W
4181  115 V ac (± 10%), 10 A,
   50/60 Hz, 1000 W
   230 V ac (± 10%), 5 A,
   50/60 Hz, 1000 W
Fuse(s)
4180  115 V ac 6.3 A, 250 V, slow blow
   230 V ac 3.15 A, 250 V, T
4181  115 V ac 10 A, 250 V, fast blow
   230 V ac 5 A, 250 V, F
Size (HxWxD)
4180  356 mm x 241 mm x 216 mm
   (14 in x 9.5 in x 8.5 in)
4181  356 mm x 241 mm x 216 mm
   (14 in x 9.5 in x 8.5 in)
Weight
4180  9.1 kg (20 lb)
4181  9.5 kg (21 lb)
Model Name Description
4180

IR Calibrator, 152 mm (6 in), –15 °C to 120 °C
Includes:

  • 4180 IR Calibrator
  • Report of Calibration (NVLAP Accredited)
  • Power Cord
  • User’s Guide
  • Documentation CD
  • Target Cover
  • Serial Cable

 

4181

IR Calibrator, 152 mm (6 in), 35 °C to 500 °C
Includes:

  • 4181 IR Calibrator
  • Report of Calibration (NVLAP Accredited)
  • Power Cord
  • User’s Guide
  • Documentation CD
  • Target Cover
  • Serial Cable

Accessories common to all models:

Accessory Description
4180-APRT

Aperture, 50 mm (2 in), 4180 or 4181

4180-CASE

Case, Carrying, 4180/4181

4180-DCAS

Case, 4180-81, Carrying, w/Wheels

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

For more information, click here!

Manuals

4180, 4181 Operators Manual (eng) 

4180, 4181 Operators Manual (chi) 

4180, 4181 Operators Manual (fre) 

4180, 4181 Operators Manual (ger) 

4180, 4181 Operators Manual (jpn) 

4180, 4181 Operators Manual (ita) 

4180, 4181 Operators Manual (rus) 

4180, 4181 Operators Manual (spa) 

4180, 4181 Operators Manual Supplement 

4180, 4181 Technical Guide 

4180/4181 Statement of Memory Volatility

brochures

4180 Series Precision Infrared Calibrators Brochure 

4180 Series Precision Infrared Calibrators Flyer 

Industrial Temperature Calibrators Workload Matrix 

Petrochemical industry calibration solutions 

Решения по калибровке для нефтехимической промышленности (Russian) 

Soluciones de calibración de la industria petroquímica (Spanish) 

Soluções de calibração do setor petroquímico (Portuguese) 

Kalibrierlösungen für die petrochemische Industrie (German) 

Solutions d'étalonnage pour l'industrie pétrochimique (French) 

石油化学産業における校正ソリューション 

 Pharmaceutical industry calibration solutions 

Решения по калибровке для фармацевтической промышленности (Russian)

Soluciones de calibración para la industria farmacéutica (Spanish) 

Solutions d'étalonnage pour le secteur pharmaceutique (French) 

Kalibrierlösungen für die Pharmaindustrie (German)

Soluções de calibração do setor farmacêutico (Portuguese)

医薬品産業における校正ソリューション 

Power and utilities industry calibration solutions 

 Soluciones de calibración de la industria de energía y servicios (Spanish)

Решения в области калибровки приборов для измерения при производстве электроэнергии и эксплуатации инженерно-технических систем 

Soluções de calibração do setor de serviços públicos e energia (Portuguese) 

Kalibrierungslösungen für die Energie- und Versorgungsindustrie (German) 

 Solutions d'étalonnage pour le secteur de la distribution d'énergie (French) 

電力産業における校正ソリューション 

Temperature Calibration Applications and Solutions 

Etalonnage de la température APPLICATIONS ET SOLUTIONS 

Calibración de temperatura Aplicaciones y soluciones 

Calibração de Temperatura Aplicações e soluções

Temperaturkalibrierung Anwendungen und Lösungen

Application notes

Emissivity compensation for Fluke Calibration 4180 Series Precision Infrared Calibrators

Infrared Temperature Calibration 101 (English)

Einführung in die Infrarot-Temperaturkalibrierung 101 (German) 

Etalonnage en températures infrarouges 101 (French) 

Calibración de temperatura infrarroja 101 (Spanish) 

Infrared Thermometer Calibration -- A Complete Guide 

赤外線放射温度校正の基礎(日本語)

Software

IR Configuration Utility v1.0

Firmware

4180 Firmware Update v. 1.14

4181 Firmware Update

Video

How does emissivity make a temperature difference?

Webinars

How to Calibrate an Infrared Thermometer

How to Create an Infrared Thermometer Uncertainty Budget

Infrared Temperature Calibration 101