Online Buying Store Product Details

{{image.AltTag}} {{image.AltTag}}
Default Image Default Image

{{details.product.ModelName}}

Sku: {{details.product.ModelNumber}}

Price: {{(details.product.BundleUnitCost || details.product.UnitCost) | currency : 'R' : 2}} (Excl. VAT)

Now: {{(details.product.BundleSalePrice || details.product.SalePrice) | currency : 'R' : 2}} (Excl. VAT)

Amprobe HD110C IP67 Heavy Duty Multimeter
OUT OF STOCK, Contact office for lead time
Delivery time for this product is 5-7 business days
{{details.product.PriceUnits}}
Please fill out this field...
Please enter a number...
Please enter at least 1...
Please enter at max 999999...

You purchased this item on {{details.product.OrderHistory[0].OrderDate | date : 'yyyy-MM-dd'}}

Personal Greeting

The Amprobe HD110C Heavy Duty Multimeter is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. Its made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts.

Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistant to at least eight feet. The HD110C has an extended voltage measurement capability of 1500 V DC and 1000 V AC, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV.

  • Highest voltage capability, measuring to 1500 V DC and 1000 V AC
  • CAT IV 1000 V rated
  • Special sealing for environment and water resistance: IP67 rated
  • Constructed with drop-resistant housing and PCB mounting
  • Magne-Grip™ holster, frees both hands for work
  • Includes high voltage test leads with threaded alligator clips
  • Display 3-1/2 digit LCD, 1999 counts, with annunciators
  • Automatic polarity indication
  • Low battery indication
  • Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F2
  • Flame retardant, high-impact thermoplastic case
  • Resistance ranges 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ
FEATURE HD110C HD160C
DC Voltage 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V 1000.0 mV, 10.000 V, 100.00 V, 1500.0 V
AC Voltage 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V 1000.0 mV, 10.000 V, 100.00 V, 1000.0 V
Current AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A 100.00 µA, 1000.0 µA, 10.000 mA, 100.00 mA, 400.0 mA, 2.000 A
Resistance 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO 1000.0 O, 10.00 kO, 100.00 kO, 1000.0 kO, 10.000 MO, 40.00 MO
Diode
Continuity
Frequency 100.00 Hz, 1000.0 Hz, 10.000 kHz, 100.00 kHz, 1000.0 kHz, 10.000 M Hz
Capacitance 40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF
Temperature -4 °F → 2372 °F (-20 °C → 1300°C)
True-rms
Specifications
DC Volts range: 200 mV, 2 V, 20 V, 200 V, 1500 V
DC Volts resolution: 0.1 mV
DC Volts accuracy: All ranges ±(0.1 % rdg+2 dgts)
DC Volts input impedance: 10 MO
DC Volts OL protection: >1500 V DC/1000 V AC rms
DC Volts transient protection: >12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV
AC Volts (45 Hz to 2 kHz) ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V
AC Volts (45 Hz to 2 kHz) resolution: 0.1 mV
AC Volts (45 Hz to 2 kHz) accuracy: 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts),
AC Volts (45 Hz to 2 kHz) accuracy: 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts)
AC Volts (45 Hz to 2 kHz) accuracy: 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts)
AC Volts (45 Hz to 2 kHz) accuracy: 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts)
AC Volts (45 Hz to 2 kHz) input impedance: 10 MO
AC Volts (45 Hz to 2 kHz) OL protection: 1500 V DC/1000 V AC rms
AC Volts (45 Hz to 2 kHz) transient protection: 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV.
DC Current range: 200 µA, 2 mA, 20 mA, 200 mA, 2 A
DC Current resolution: 0.1 µA
DC Current accuracy: 200 µA to 20 mA ±(0.5 % rdg+2 dgts)
DC Current accuracy: 200 mA to 2 A ±(1.0 % rdg+2 dgts)

 

For more information, please click here:

Datasheet »

Product Manual »