Fluke 114 digital multimeter is the ideal choice for go/no-go testing
Designed for easy one-handed operation, the compact Fluke 114 True RMS digital multimeter is the perfect troubleshooting tool for go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. And you can use the LoZ function to identify so-called ghost voltage and prevent false readings.
The Fluke 114 displays True-RMS voltage and current readings with 6000 count resolution, and tests frequency, continuity and resistance. A large white LED backlight aids work in poorly lit areas. And its easy-open battery access door makes battery changes easy.
A great choice for everyday troubleshooting, the Fluke 114 Electrical Multimeter is CAT III 600 V safety rated and is a compact True-RMS meter.
Fluke 114 multimeters are independently tested for safe use in CAT III 600V environments
Other useful features:
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to + 50°C
Storage temperature
-40°C to + 60°C
Battery type
9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
DC volts
6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V
Auto volts
600.0 V / 0.1 V
2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V
Continuity
600 Ω / 1 Ω
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
0.9% + 1
40.00 MΩ / 0.01 MΩ
5% + 2
1. All ac voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical & General Specifications
Size
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight
550 g
Warranty
3 years
Fluke 114 Digital Multimeter
Includes:
For more informtion, click here.
Manuals
Data Sheets
Selection Guide