The Fluke 117 Digital Multimeter includes integrated non-contact voltage detection to help get the job done faster

Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.

Engineered and Tested with Your Safety on the Job in Mind

We test Fluke 117 multimeters for safe use in CAT III 600 V environments and we have designed in several features to make it easier and faster for you to get the measurements you need, including:

  • Measures 10 A (20 A overload for 30-seconds)
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with an holster with probe holders for easy storage
  • Features compact ergonomic design for one-handed operation
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated
  • A large white LED backlight to improve measurement visibility in poorly lit areas
  • VoltAlert™ technology for fast, go/no go non-contact voltage detection
  • AutoVolt and low input impedance modes to provide faster, more accurate readings

Key features

  • Accurate, easy-to-use multimeter with integrated VoltAlert™ technology for non-contact voltage detection
  • Features AutoVolt automatic AC/DC voltage selection
  • Provides low input impedance to help prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Features True RMS capabilities for accurate measurements on non-linear loads

Specifications

Maximum voltage between any terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2

Fuse for A input

11 A, 1000 V FAST Fuse (Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to +50°C

Storage temperature

-40°C to +60°C

Battery type

9 volt Alkaline, NEDA 1604A / IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V

Accuracy

±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution

600.0 V / 0.1 V

Accuracy

2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)

AC millivolts¹ True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts¹ True RMS

Range/resolution

6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

AC amps True RMS (45 Hz to 500 Hz)

Range/resolution

6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy

1.5% + 3
20 A continuous overload for 30 seconds max

DC amps

Range/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy

1.0% + 3
20 A continuous overload for 30 seconds max

Hz (V or A input)²

Range/resolution

99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz

Accuracy

0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

Mechanical and General Specifications

Size

167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight

550 g

Warranty

3 years

Includes:

  • 4 mm silicone test lead set
  • Holster
  • User manual