The Fluke 117 Digital Multimeter includes integrated non-contact voltage detection to help get the job done faster
Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.
Engineered and Tested with Your Safety on the Job in Mind
We test Fluke 117 multimeters for safe use in CAT III 600 V environments and we have designed in several features to make it easier and faster for you to get the measurements you need, including:
Key features
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Fuse for A input
11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to +50°C
Storage temperature
-40°C to +60°C
Battery type
9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
±([% of reading] + [counts]): 0.5% + 2
DC volts
6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
Auto volts
600.0 V / 0.1 V
2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS
6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
Continuity
600 Ω / 1 Ω
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
0.9% + 1
40.00 MΩ / 0.01 MΩ
5% + 2
Diode test
2.00 V / 0.001 V
0.9% + 2
Capacitance
1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
1.9% + 2
> 1000 μF
5% + 20%
Lo-Z capacitance
Range
1 nF to 500 μF
10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)
6.000 A / 0.001 A 10.00 A / 0.01 A
1.5% + 3 20 A continuous overload for 30 seconds max
DC amps
1.0% + 3 20 A continuous overload for 30 seconds max
Hz (V or A input)²
99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz
0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight
550 g
Warranty
3 years
Includes:
fFor more information, click here.