What Once Took Two People, Now Takes One
Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.
The iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires.
Safety Conformance IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV
Electrical Specifications
AC Current via Jaw
Range
999.9 A
Resolution
0.1 A
Accuracy
2% ± 5 digits (10-100 Hz)
5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz)
3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
999.9 A / 2500 A (45 Hz – 500 Hz)
0.1 A / 1 A
3% ± 5 digits
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Position Sensitivity
Distance from Optimum
i2500-10 Flex
i2500-18 Flex
Error
A
0.5 in (12.7 mm)
1.4 in (35.6 mm)
±0.5%
B
0.8 in (20.3 mm)
2.0 in (50.8 mm)
±1.0%
C
2.5 in (63.5 mm)
±2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
2% ± 5 digits
AC Voltage
600 V /1000 V
0.1 V / 1 V
1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
600.0 V /1000 V
1% ± 5 digits
Frequency – Via Jaw
5.0 – 500.0 Hz
0.1 Hz
0.5% ± 5 digits
Trigger Level
5 – 10 Hz, ≥ 10 A
10 – 100 Hz, ≥ 5 A
100 – 500 Hz, ≥ 10 A
Frequency via Flexible Current Probe
5.0 to 500.0 Hz
5 to 20 Hz, ≥ 25 A
20 to 100 Hz, ≥ 20 A
100 to 500 Hz, ≥ 25 A
Resistance
600 Ω/6 kΩ/60 kΩ
0.1 Ω/1 Ω/10 Ω
Mechanical Specifications
Size (L x W x H)
277 x 88 x 43 mm (55 mm for remote unit)
Weight
350 g
Jaw Opening
34 mm
Flexible Current Probe Diameter
7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature
-10°C to +50°C
Storage Temperature
-40°C to +60°C
Operating Humidity
Non condensing (< 10°C)
≤ 90% RH (at 10°C to 30°C)
≤ 75% RH (at 30°C to 40°C)
≤ 45% RH (at 40°C to 50°C)
(Without Condensation)
Operating Altitude
2,000 meters
Storage Altitude
12,000 meters
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006
ETSI EN 300 489 V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID: T68-F381
RSS-210 IC: 6627A-F381
Temperature Coefficients
Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
Wireless Frequency
2.4 GHz ISM Band 10 meter range
Safety Compliance
ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.
Double Insulation Clearance
Per IEC 61010-2-032
Double Insulation Creepage
Per IEC 61010-1
Agency Approvals
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®Includes:
For more information, click here.
Manuals