General Specifications |
Number of Phases |
1 to 3 |
Weight |
Approx. 5 kg (11 lb) |
Size |
150 x 237 x 315 mm |
5.9 x 9.3 x 12.4 in |
On-board Printer |
No |
Display |
Color, 5.7 in / 144 mm - 320 x 240 pixel |
User-selectable background lighting and contrast. |
Bandwidth |
DC to 3 MHz or DC to 10 MHz depending on input module |
Basic Accuracy |
0.2%, 0.1% or 0.03% depending on input modules |
Sampling Rate |
0.33 MHz or 1 MHz depending on input modules |
Voltage Input Range |
0.3 V to 1000 V |
Current Input Range (direct, not via shunt) |
0.03 mA to 20 A depending on input module |
Memory for Configurations |
4 MB |
Memory for Settings |
0.5 MB |
Fast Fourier Transformation (FFT) |
To the 40th harmonic |
RS232/USB Interface |
Standard |
PI1 Process interface (8 analog/impulse inputs and 4 analog outputs) |
Optional |
IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s) |
Optional |
Fluke NormaView PC software (for data download, analysis and report writing) |
Standard |
Basic Functions |
Fast Fourier Transformation (FFT) |
Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time. |
Measured values: U, I, P per phase |
Order: 1st to 40th harmonics, maximum half sample frequency |
Digital Oscilloscope (DSO) |
Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion. |
Integration function (energy) |
Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available. |
Vector Display |
Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal. |
Recorder |
Display of average values over time for trend determination. |
RAM data memory |
Storing of sample and average values; setting of start and stop conditions. |
From the RAM approximately 4 MB are available for the storage of measured values. |
Configuration |
Set up the analyzer to measure and display data in the format required. |
Ambient Conditions |
Working Temperature Range |
5°C to 35°C (41°F to 95°F) |
Storage Temperature Range |
-20°C to 50°C (-4°F to 122°F) |
Housing Material |
Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. |
Climatic Class |
KYG DIN 40040, max. 85% relative humidity, non-condensing. |
Power supply |
85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models. |
Measuring Inputs |
Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. |
Operation |
Membrane keyboard with cursor – function keys and direct functions. |
Connections |
Rear panel of the 3-phase Analyzer |
Measured Values |
|
Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values.
- Urms effective value, Urm rectified mean, Um mean value
- Up-, Up+, Upp peak values
- Ucf crest factor Ucf, Uff form factor
- Ufc fundamental content
- Uthd distortion factor DIN, IEC
- Irms effective value, Irm rectified mean, Im mean value
- Ip-, Ip+, Ipp peak values
- Icf crest factor Icf, Iff form factor
- Ifc fundamental content
- Ithd distortion factor DIN, IEC
- P active power [W]
- Q reactive power [Var]
- S apparent power [VA]
- ë, cos. phase angular
- Integral function for active power P, reactive power Q, apparent power S, voltage (Um) and current (Im),
- Number of digits 4 or 5 dependent on measured value.
|
Frequency and Synchronization |
Range |
DC and 0.2 Hz to sample rate |
Accuracy |
±0.01% of measured value (reading) |
|
- Channels which can be selected: all U/I or external input.
- One of three low pass filter with different frequencies can be switched into the signal.
- The frequency is always visible on the top of the screen.
- The BNC synchronization socket on backside of the instrument can be used either as input or output.
- The input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50 V.
- The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency).
|
Configuration Memory |
|
Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument. |
Interface |
|
RS232 interface for upload of firmware and data exchange with the PC. A printer can be connected over an external converter. |
Options |
IEEE 488.2 / 1 MBit/s |
Ethernet / 10 MBit/s or 100 Mbit/s |
Standards and Safety |
Electrical Safety |
EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) |
Degree of pollution 2, safety Class I |
EN 61558 for transformer |
EN 61010-2-031/032 for accessories |
Maximum inputs |
For voltage inputs Measurement range 1000 Veff, 2 kVpeak |
For current inputs Measurement range 10 Aeff, 20 Apeak |
Test voltage |
Net input |
case (protective conductor): 1.5 KV AC |
Net connection |
Measurement input: 5.4 kV AC |
Measurement inputs |
Case: 3.3 kV AC |
Measurement input |
input: 5.4 kV |
Electromagnetic susceptibility |
Emission |
IEC 61326-1, EN 50081-1, EN 55011 Class B |
Immunity |
IEC 61326-1 / Annex A (industrial sector), EN 50082-1 |