Online Buying Store Product Details

{{image.AltTag}} {{image.AltTag}}
Default Image Default Image

{{details.product.ModelName}}

Sku: {{details.product.ModelNumber}}

Fluke 107 Palm-sized Digital Multimeter
{{details.product.PriceUnits}}
Please fill out this field...
Please enter a number...
Please enter at least 1...
Please enter at max 999999...

You purchased this item on {{details.product.OrderHistory[0].OrderDate | date : 'yyyy-MM-dd'}}

Personal Greeting

The Fluke 107 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.

Key features

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Backlit display
  • Data hold
  • Diode test, plus frequency and duty cycle measurements

Specifications: Fluke 107 Palm-sized Digital Multimeter

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Accuracy Specifications
Function Range Resolution Accuracy
AC Volts
(40 Hz to 500Hz)1
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
Diode Test2 2.000 V 0.001 V 10 %
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4
Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty Cycle4 1 % to 99 % 0.1 % 1 % typical 5
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  5. Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 600 V 1 >10 MΩ <100 pF 2 >60 dB at dc,
50 Hz or 60 Hz
AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz
DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP Rating IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment IEC 61326-1: Portable
Electromagnetic Compatibility Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.

Fluke 107 Palm-sized Digital Multimeter

  • Fluke 107 Palm-sized Digital Multimeter with Frequency, Diode Test
  • Tl75 Hard Poin Test Lead Set
  • 2 AAA Batteries (Installed)
  • User's Manual
  • Smart Strap

 

Accessories: Fluke 107 Palm-sized Digital Multimeter

Clips 

  • Fluke AC220 SureGrip™ Alligator Clips
  • Fluke AC280 SureGrip™ Hook Clips
  • Fluke AC283 SureGrip™ Pincer Clips
  • Fluke AC285 SureGrip™ Alligator Clips
  • Fluke AC87 Heavy Duty Bus Bar Clip Set
  • Fluke AC89 Heavy Duty Insulation Piercing Test Clip

Test probes

  • Fluke TP1 Slim Reach Test Probes
  • Fluke TP220 SureGrip™ Industrial Test Probes
  • Fluke TP4 Slim Reach Test Probes
  • Fluke TP80 Electronic Test Probes

Cases

  • Fluke C100 Universal Carrying Case
  • Fluke C800 Meter and Accessory Case
  • Fluke C25 Large Soft Case for DMMs
  • Fluke CAMO-C25 Camouflage Carrying Case

Automotive

  • Fluke PV350 Pressure Vacuum Module
  • Fluke TL28A Automotive Test Lead Set

Probes 

  • Fluke 80T-150UA Universal Temperature Probe

Visual IR thermometers 

  • Fluke 80TK Thermocouple Module

Test leads 

  • Fluke TL220 SureGrip™ Industrial Test Lead Set
  • Fluke TL223 SureGrip™ Electrical Test Lead Set
  • Fluke TL224 SureGrip™ Insulated Test Leads
  • Fluke TL71 Premium Test Lead Set
  • Fluke TL221 SureGrip™ Test Lead Extension Set
  • Fluke TL238 SureGrip™ Test Lead Set for High Energy Environments
  • Fluke TL26A 60 in. 5-Way Test Lead Set
  • Fluke TL27 Heavy Duty Test Lead Set
  • Fluke TL75 Hard Point™ Test Lead Set
  • Fluke TL76 2mm/4mm Test Lead Set