The Fluke 3130 Portable Pneumatic Pressure Calibrator is ideal for calibrating pressure transmitters, transducers, gauges and similar devices. The Fluke 3130 contains everything you need to generate, control and measure pressure, as well as read the output of the device under test (DUT).

  • Measure and generate pressures from vacuum to 2 MPa (300 psi, 20 bar)
  • Internal pump can generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar)
  • Supply pressure connection allowing the use of external gas supply up to 2 MPa (300 psi, 20 bar)
  • Includes variable volume for fine adjustment of pressures
  • Pressure measurement accuracy of ± (0.025 % reading + 0.01 % FS)
  • Electrical measurement and 24 volt supply for close looped calibrations
  • Measure or generate 4 to 20 mA
  • Measure 0 to 30 V dc
  • Powered by internal, high capacity, NiMH battery or universal ac mains adapter
  • Compatible with Fluke 700P and 750P Pressure Modules

Pressure generation and control

The internal, motorized pump provides an easy, efficient alternative to time consuming, tiring hand pumps. For applications that involve filling a large volume with pressure, the 3130 allows for connection to an external gas supply such as compressed plant air. The pressure can be fine-tuned using the variable volume.

Pressure measurement

The Fluke 3130 offers an onboard pressure sensor with a full scale of 2 MPa (300 psi, 20 bar) and an accuracy of ± 0.025 % reading + 0.01 % FS (includes precision, one-year stability, uncertainty of the calibration standard, and temperature effects). In addition, the Fluke 3130 can be used with the Fluke 700P pressure module series to improve measurement performance across the entire range.

Electrical measurement

The Fluke 3130 offers electrical measurement capabilities for calibrating pressure transducers and transmitters, including measurements of 4 to 20 mA or 0 to 30 V dc. In addition, the 3130 provides 24 V dc supply to power the device under test and can generate current in the 4 to 20 mA range.

Portability

The Fluke 3130 is built into a ruggedized case with internal storage for power supply, test leads, and fittings. In addition, it includes a rechargeable, NiMH battery, allowing for approximately 50 hours of operation. When using the internal pump, the battery is sufficient to provide up to 100 calibration cycles to 300 psi. The battery is recharged by simply plugging the unit in using the included universal mains adapter.

Automation

In the field, the 3130 can be connected to a personal computer with the Fluke Calibration 700SC Serial Interface Cable Assembly », to log data and send instructions using Fluke Calibration COMPASS for Pressure » software.

Environmental

Operating temperature -10 °C to +50 °C
Storage temperature -20 °C to +60 °C
Power requirements 12 V dc (Universal ac adapter/charger supplied)
Battery Internal 3800 mAh advanced NiMH pack

Operating time

On full charge Approx 50 hours (Measure only or external air; no
pump)
Using internal pump Approx 100 calibration cycles to 300 psi

Physical

Dimensions 15.25 in L x 12 in W x 7 in D
Weight ~7 kg (15 lb)
EMI/RFI conformance EN61326:2006 Annex A
Connectors/ports 1/8 in NPT (External supply port and test port)
Included accessories Manual, NIST-traceable certificate, test leads, universal
ac adapter/charger

Ranges

Pressure (internal pump) -80 kPa to 2 MPa (-12 to 300 psi, -0.8 to 20 bar)
Pressure (external air) 0 to 2 MPa (0 to 300 psi, 0 to 20 bar)
mA 0 to 24.000 mA
Volts 0 to 30.000 V dc
Engineering units psi, bar, mbar, kPa, MPa, kgf/cm2, mmH2O @ 4 °C,
mmH2O @ 20 °C, cmH2O @ 4 °C, cmH2O @ 20 °C,
inH2O @ 4 °C, inH2O @ 20 °C, inH2O @ 60 °F, mmHg
@ 0 °C, inHg @ 0 °C

Instrumental measurement uncertainty

Pressure ±(0.025 % of reading + 0.01 % FS)
mA ±(0.015 % of reading + 0.002 mA)
Volts ±(0.015 % of reading + 0.002 V)

Temperature effect (all functions)

No effect on accuracy on all functions from 15 °C to 35 °C
Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C
Model Name Description
3130-G2M

Portable Pressure Calibrator with US, EUR, UK, and China/Australia line cords (standard calibration)

3130-G2M/C

Portable Pressure Calibrator with US, EUR, UK, and China/Australia line cords (ISO 17025 accredited calibration)

Accessories common to all models:

Accessory Description
Fluke 750P Series Pressure Modules

Pressure Module Series

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

700SC

Serial Interface Cable Assembly