Online Buying Store
Request for Quote Store
{{minicart.wishlist.length}} {{minicart.cartList.length}}
You have no items in your shopping cart.
You have 1 item in your shopping cart.
{{multiCartItemsStr.replace('[COUNT]', minicart.cartList.length)}}
{{cartItem.ProductName}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
Qty: {{cartItem.Quantity | number : 2}}

Item Qty
{{cartItem.ProductName}} {{cartItem.ProductName}}
SKU: {{cartItem.ProductSku}}
{{cartItem.Quantity | number : 2}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
You have no items in your shopping cart.
Image Item Qty
{{cartItem.ProductName}} {{cartItem.ProductName}}
SKU: {{cartItem.ProductSku}}
{{cartItem.Quantity | number : 2}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
You have no items in your shopping cart.
Description Created
{{savedCart.Description}} {{savedCart.CreateDate | date : 'yyyy-MM-dd HH:mm'}}
SKU Product Name Unit Cost Qty Line Total
{{cartItem.ProductSku}} {{cartItem.ProductName}} {{cartItem.UnitCost | currency : 'R' : 2}} {{cartItem.Quantity | number : 2}} {{cartItem.UnitCost * cartItem.Quantity | currency : 'R' : 2}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
You have no items in your saved shopping cart.
You have no items in your wishlist.
Status Order No. Order Date Ship To Order Total Pay Total Balance
Bill Me Later Open Ready To Ship Shipped Picked Up Cancelled Incomplete On Hold Back Ordered Returned {{order.Status}}
{{order.OrderID}} {{order.OrderDate | date : 'yyyy-MM-dd'}} {{order.ShipFirstName}} {{order.ShipLastName}}, {{order.ShipAddress1}} {{order.ShipAddress2}}, {{order.ShipCity}}, {{order.ShipState}} {{order.ShipZipcode}} {{order.GrandTotal | currency : 'R' : 2}} {{order.PayTotal | currency : 'R' : 2}} {{order.GrandTotal - order.PayTotal | currency : 'R' : 2}}
Logo

Comtest Store RFQ

Grid View List View Sorting: Normal Sorting: Price Low to High Sorting: Price High to Low Sorting: New Arrivals Sorting: Brand A-Z Sorting: Brand Z-A

Calibration Bath Fluids

sku Product SKU:  FCL-Calibration Bath Fluids

Fluke Calibration carries a full line of bath fluids covering temperature ranges from –100°C to 550°C.

Finally, there’s a convenient source for small quantities of bath fluids for any temperature range. Why pay for more than you need?

Viscosity, volatility and other properties that change with temperature affect the performance of fluids in controlled baths and circulators. Fluke Calibration has tested and used each of the fluids we sell. Over the ranges recommended in the following table, each fluid remains at a low enough viscosity to be adequately pumped or stirred. Whether your application is industrial or critical lab calibration work, Hart fluids give you top performance and stability.

For temperature ranges too high for oils, we have a bath salt with a viscosity in the molten state similar to the viscosity of water. For your convenience, it is shipped in a granular form, making it easy to fill your bath.

Between its melting point of 150°C and 550°C, this salt has the highest temperature stability and uniformity available in a bath fluid. It does not smoke like oils or give off dust like “sand" or fluidized alumina baths. Check with your bath manufacturer before using this salt to make sure your equipment is compatible. Fluke Calibration offers three standard bath models and custom-designed units for use with this salt.

Fluid specifications 
It’s important to understand a few specifications before selecting a bath fluid. We’ve seen bath fluids advertised with a temperature range that spans from the freezing point to the flash point or beyond.

For example, type 710 silicone oil has a freezing point of –22°C, but freezing point has nothing to do with the point at which the oil becomes so thick it cannot be properly stirred. Type 710 oil should really only be used down to about 80°C. It’s a viscosity issue, not a freezing-point issue. Usable range is the question. Suitability for calibration work is the specification that counts.

The usable viscosity range is determined by your bath’s stirring or pumping design. Fluke Calibration baths can be operated using fluids with up to 50 centistokes viscosity. This gives you additional usable range in the lower temperature levels of the fluid.

Some baths advertised as calibration baths require fluids with 10 centistokes or less viscosity to operate properly. The usable ranges in our table on the previous page assume the use of a Fluke bath.

In addition to range and viscosity issues, there are a number of other issues to consider when choosing a bath fluid. The other considerations are:

  • Thermal characteristics
  • Lifetime
  • Change in characteristics due to temperature cycling
  • Absorption of water from the air
  • Vaporization—fumes and fume hood requirements
  • Expansion due to heat
  • Contamination—mixing oils or introducing contamination with unclean probes
  • Conductivity properties
  • Effects of using fluids outside of their range—fire, explosion, polymerization
  • Effects of altitude on boiling point

    ZAR -1

    Custom Temperature Calibration Baths

    sku Product SKU:  FCL-Custom Temperatures Calibration Baths

    Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. However, if your needs aren’t met by our standard sizes and temperature ranges, then we can build a custom bath that is as reliable and as fine a calibration instrument as any standard bath we manufacture.

    Some of the examples of the custom baths we have built include significant bath tank changes (taller, wider or deeper), change in the temperature range, different height or particular shape, faster heat and cool rates. We have built baths that require windows or custom dimensions to accommodate test fixtures. We can do all of this and more. No other manufacturer supplies custom baths to their customers, but we do.

    Our engineers and designers know more about temperature calibration baths than anyone else. You’ll find our baths throughout the best national and international temperature calibration labs. It does not matter what type of calibration application you have – oceanography, missile optics, infrared, sensor manufacturing, semiconductor, renewable energy, LIG manufacturing, or down-hole tools. We have probably already built baths to do the job.

     

     

    ZAR -1

    IMG-Integration-software

    Fluke Calibration MET/CONNECT™ Calibration Integration Software

    sku Product SKU:  FCAL-METCAL-TESTEQUIPASSET-SOFTWARE

    Integrate MET/CAL Calibration Management Software to your workflow with MET/CONNECT.

    MET/CONNECT™ is the hub of a fast-growing community of mainline calibration software providers. These companies have partnered with Fluke Calibration to support MET/CAL automation. Whatever calibration management system you use, MET/CONNECT unlocks calibration and workflow automation in your lab.

    MET/CONNECT partners:

    • Indysoft
    • AssetSmart
    • Qualer
    • MET/TEAM®

    ZAR -1

    FACL-9142-2

    Fluke Calibration 9142 | 9143 | 9144

    sku Product SKU:  FCAL-9142-3-4

    Product overview: Fluke Calibration 9142 Field Metrology Well

    Small dry wells for big field applications

    The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.

    Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.

    High performance for the industrial environment

    Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport.

    Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 °C to 33 °C.

    ZAR -1

    Fluke Calibration E-DWT Electronic Deadweight Tester

    sku Product SKU:  FCAL-E-DWT

    E-DWT-H breaks new ground, improving the hydraulic pressure calibration process. E-DWT-H is an electronic calibrator designed to replace mechanical, piston-cylinder and weight based deadweight testers. It’s a lighter, easier-to-use deadweight tester alternative that is at home in the lab or instrument shop, as well as in the field performing in-situ calibrations and tests. This complete hydraulic pressure calibration system combines the convenience and precision of continuous, realtime electronic pressure measurement with the simple and direct operation of high quality operator controlled pressure generation hardware. E-DWT-H one year measurement uncertainty is ± 0.02 % of reading with ranges up to 30,000 psi. It can be configured to provide this uncertainty from its full scale down to 1 % of its range. Built-in pressure generation and control hardware allow the operator to fill and prime the system under test and generate and precisely adjust pressure throughout the range with ease.

    Broad workload coverage 
    The E-DWT-H has the operational versatility to calibrate and test a broad range of pressure measuring instruments including:

    • Analog gauges
    • Transducers
    • Calibrators
    • Sensors
    • Transmitters

     

    AutoTest™ lets E-DWT operators quickly define test points and adjust all of the range-dependent settings with a single function. 
    The resolution and stability test used by the RPM4-E-DWT are set according to the range of the device under test. The upper limit setting is also set and provides range-based warnings and overpressure protection. While running AutoTests, the operator is prompted to set each sequential test point and test data is stored in the RPM4-E-DWT for recall or download. Typical test setup is quick and easy, but more complex tests can also be stored and reused.

    Deadweight tester performance with digital measurement convenience 
    E-DWT-H offers precision, low measurement uncertainty and the stability over time of a conventional deadweight tester without the inconveniences associated with the piston-cylinders, weights, hand pumps, and interconnecting plumbing.

    • No weights to load and unload or regularly send out for calibration
    • No need to know and correct for local gravity or ambient temperature
    • No piston-cylinder changes; switch Q-RPT ranges in seconds
    • Not sensitive to level or vibration
    • Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses
    • Operates in any unit of measure while deadweight tester is typically limited to the pressure unit stamped on the mass
    • Perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
    • On-board, AutoTest calibration routines and data acquisition
    • Interfaceable with a PC or laptop to allow for automated data acquisition
    • Two year calibration interval supported at measurement uncertainty of ± 0.025% of reading.
    • Easily recalibrated without crossfloating. Automated calibration of E-DWT-H is possible using COMPASS® for Pressure software.

     

    Versatility to cover a broad workload in a variety of environments 
    The E-DWT-H is at home in metrology and calibration labs, on the production floor or in the field. It operates with Sebacate calibration fluid, mineral oil, Skydrol® and other liquids. An optional battery/charger pack supports up to eight hours of operation away from line power.

    All the features you expect in today’s state-of-the-art instruments, including:

    Accuracy and performance 

    • One-year measurement uncertainty is ± 0.02% of reading from 10% to 100% with one Q-RPT, and from 1% to 100% with two Q-RPTs
    • Low torque variable volume allows for pressure generation up to 200 MPa (30,000 psi) with minimal physical effort
    • Separate fine adjustment tool for maximum, superfine control resolution
    • User defined resolution and ready limits enable user to optimize performance based on DUT specifications
    • High pressure isolation valve and pressure relief valve protect the low pressure reference transducer from over pressure when high pressure reference transducer is active

    Ease of use

    • AutoRange feature optimizes measurement and safety features for the specific range of the instrument being calibrated
    • Simple rezeroing while vented at atmospheric pressure
    • Simple, objective pressure “ready/not ready indicator with user adjustable criteria to ensure repeatable results among operators
    • Not dependent on local gravity or ambient temperature
    • Sets and reads any pressure value directly in any unit of measure, without moving weights
    • Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation
    • Optional foot switch accessory allows hands-free data collection when running AutoTests

    Portability

    • Rechargeable battery pack option for eight hours of field operation
    • Everything to set, adjust and read pressure in one compact, transportable package
    • Optional shipping/carrying case with handles and wheels allows for easy transport to field application
    • Proven rugged and weatherproof design with room for accessories.

     

     

    Automation

    • RS232 interface allows for real time automated data collection and customized report generation using DHI’s COMPASS® for Pressure calibration software



    Free upgrades

    • Flash memory for simple and free embedded software upgrades from


    www.dhinstruments.com

     

     

    Automate data collection and manage calibration assets with COMPASS® for Pressure software

    E-DWT can run stand-alone tests and collect test data. Test data can be downloaded over the RPM4-E-DWT’s RS232 interface. 

    The RPM4-E-DWT’s RS232 interface can also be used to run the E-DWT with COMPASS® for Pressure software or user developed software. 

    COMPASS® for Pressure software is universal pressure calibration software for the laboratory, which can be used to run simple or complex tests with multiple instruments. The user can create his/her own calibration report, and data can be exported to Fluke MET/CAL® Plus Calibration Management Software.

    The support you need, when you need it 
    DHI’s calibration, testing and repair services are dedicated to satisfying your needs quickly and at a fair cost while maintaining the unmatched level of quality that is our trademark.

    DHI’s calibration laboratories are accredited by the American Association for Laboratory Accreditation (A2LA) for conformance to ISO Guide 17025. 

    As a Fluke company, DHI has access to global calibration and repair facilities to keep your hardware in top working order. 

    If you need training for yourself or your staff, DHI offers a broad range of classes including: the principles and practices of pressure calibration, advanced pressure metrology, gas flow calibration using a DHI molbloc/molbox system, set up and operation of COMPASS® for Pressure calibration assistance software, and much more.

    Fluke’s commitment to support provides additional benefits as well, including invitations to software user group meetings and conferences, periodic email bulletins and a pressure and flow newsletter

    ZAR -1

    5730A High Performance Multifunction Calibrator

    sku Product SKU:  FCL-5730A

    The new gold standard in electrical calibration

    Since 1988, the 5700A family has set the standard for multifunction calibrator performance in calibration laboratories around the world. Now the time has come to advance this best-in-class calibrator, taking advantage of twenty-first century technology and usability.

    The Fluke Calibration 5730A High Performance Multifunction Calibrator is the culmination of years of engineering development, customer research and industrial design, to bring to market the new “gold standard” in electrical multifunction calibration.

    High performance for the future

    Like its predecessors, the 5730A calibrates a wide range of digital multimeters, up to long-scale 8.5 digit DMMs, as well as RF voltmeters when equipped with the wideband option. But this new model features improved specifications that will help you increase test uncertainty ratios (TURs) and increase test confidence. What’s more, the improved specifications will reduce your need to guardband, giving you confidence and peace of mind in your calibrations.

    • Improved performance specifications for ac voltage, ac current and resistance
    • 6.5 inch VGA capacitive touch screen with full color graphical user interface
    • Visual Connection Management™ output terminals guide connections
    • Graphical user interface in nine languages
    • Compatible with 52120A and 5725A amplifiers
    • Full MET/CAL® compatibility with 5700A and 5720A procedures
    • Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards; 30 MHz and 50 MHz wideband output options available