Request for Quote Store
{{minicart.wishlist.length}} {{minicart.cartList.length}}
You have no items in your shopping cart.
You have 1 item in your shopping cart.
{{multiCartItemsStr.replace('[COUNT]', minicart.cartList.length)}}
{{cartItem.ProductName}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
Qty: {{cartItem.Quantity | number : 2}}

Item Qty
{{cartItem.ProductName}} {{cartItem.ProductName}}
SKU: {{cartItem.ProductSku}}
{{cartItem.Quantity | number : 2}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
You have no items in your shopping cart.
Image Item Qty
{{cartItem.ProductName}} {{cartItem.ProductName}}
SKU: {{cartItem.ProductSku}}
{{cartItem.Quantity | number : 2}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
You have no items in your shopping cart.
Description Created
{{savedCart.Description}} {{savedCart.CreateDate | date : 'yyyy-MM-dd h:mm a'}}
SKU Product Name Unit Cost Qty Line Total
{{cartItem.ProductSku}} {{cartItem.ProductName}} {{cartItem.UnitCost | currency : 'R' : 2}} {{cartItem.Quantity | number : 2}} {{cartItem.UnitCost * cartItem.Quantity | currency : 'R' : 2}}
  • {{itemVariant.VariantHasText ? (itemVariant.VariantName + ': ' + itemVariant.VariantText) : (itemVariant.VariantGroup + ': ' + itemVariant.VariantName)}}
You have no items in your saved shopping cart.
You have no items in your wishlist.
Status Order No. Order Date Ship To Order Total Pay Total Balance
Bill Me Later Open Ready To Ship Shipped Picked Up Cancelled Incomplete On Hold Back Ordered Returned {{order.Status}}
{{order.OrderID}} {{order.OrderDate | date : 'yyyy-MM-dd'}} {{order.ShipFirstName}} {{order.ShipLastName}}, {{order.ShipAddress1}} {{order.ShipAddress2}}, {{order.ShipCity}}, {{order.ShipState}} {{order.ShipZipcode}} {{order.GrandTotal | currency : 'R' : 2}} {{order.PayTotal | currency : 'R' : 2}} {{order.GrandTotal - order.PayTotal | currency : 'R' : 2}}
Logo

Comtest Store RFQ

Grid View List View Sorting: Normal Sorting: Price Low to High Sorting: Price High to Low Sorting: New Arrivals Sorting: Brand A-Z Sorting: Brand Z-A

PGC-10000-AF Pneumatic Gauge Calibrator

sku Product SKU:  FCL-PGC-10000

PGC-10000-AF Pneumatic Gauge Calibrator is a special pressure gauge calibrator made up of Fluke Calibration's GPC1 Gas Pressure Controller and RPM4 A70M/A20M Reference Pressure Monitor (see the GPC1 and RPM4 brochures for details). The PGC-10000-AF is a pressure gauge calibrator that is designed to optimize the testing and calibration of analog and digital pressure gauges with ranges from less than 500 psi (3.5 MPa) to 10,000 psi (70 MPa). This special pressure gauge calibration configuration was selected by the United States Air Force as the next generation high pressure pneumatic gauge calibration system for deployment in its Precision Measurement Equipment Laboratories (PMELs) throughout the world.

With GPC1 and associated GB-152 Gas Booster, the pressure gauge calibration operator effortlessly generates and adjusts pressure to set the device under test to its cardinal point. The RPM4 then precisely measures the actual pressure applied.

Interactive RPM4 embedded software automatically sets up the pressure gauge calibration procedure based on entry of the DUT full scale and tolerance. It then steps the operator through the test, logging data and providing real time notification of in or out-of-tolerance conditions at each point. A foot pedal “ENTER switch allows the operator to trigger readings hands free.

  • Calibrate any range device in gas from less than 500 to 10,000 psi (70 MPa) FS with one compact, integrated system
  • Effortless operation; no pumping, no weight lifting
  • Includes gas booster to boost a bottled air supply as low as 400 psi (2.75 MPa) to 10,000 psi (70 MPa)
  • Easily set pressure to DUT cardinal point and read back actual pressure from the reference
  • On-board calibration routines with real time out-of-tolerance notification and data logging
  • Foot pedal “ENTER key for hands free sequence execution
  • Complete a typical high pressure gauge run in about 20 minutes (20 % ascending increments)
  • Supports 12 units of measure and custom units
  • Push button switching between gauge and absolute measurement modes
  • RS232 and IEEE-488 interfaces included; compatible with COMPASS® for Pressure software
  • Delivered with connectors and adaptors for NPT, AN4 and gland and collar DUTs
  • Includes molded, reusable transit case for shipping RPM4/HPMS transfer standard for recalibration

ZAR -1

Fluke Calibration 155X Stik Thermometer

sku Product SKU:  FCAL-155X Stik

Finally, a digital substitute for your mercury-in-glass thermometers! Accurate and repeatable to ± 0.05 °C over its full range, the 1551A/1552A “Stik Thermometer is the new “gold standard" of industrial temperature calibration. Whether working outdoors in environments where potentially explosive gases may be present or on the floor of a processing plant, the intrinsically-safe, battery operated, portable reference thermometer is designed to go where you work.
 

Features at a glance

  • Accuracy of ± 0.05 °C (± 0.09 °F) over full range
  • Intrinsically safe (ATEX and IECEx compliant)
  • Two models to choose from (-50 °C to 160 °C or -80 °C to 300 °C)
  • User-configurable temperature Trend/Stability indicator
  • Display temperature in °C or °F
  • Optional data logging to internal memory
  • 300-hour battery life
  • Percent battery-life and low-battery indicator
  • NVLAP-accredited, NIST-traceable calibration included

Thermometer probe and digital readout combined into one unit

The stainless steel probe and digital readout are fixed together and calibrated as a system. The accuracy specification is easy to understand since it includes all uncertainty components, including drift, for up to one year1. The large backlit LCD display rotates 90° degrees making it easy to read from any angle. A user-configurable stability/trend indicator lets you know when your temperature is stable enough to record an accurate measurement. A user-settable auto-off function extends typical battery life to three hundred hours. A low-battery indicator and stop-measure function prevent erroneous measurements from being made due to low battery life. A simple three-point calibration function allows you to easily and accurately calibrate the “Stik" Thermometer. Data logging to internal memory of up to 10,000 time-stamped measurements is optionally available.

Why calibrate process temperature sensors?

Because temperature greatly effects the accuracy of a volumetric measurement, process manufacturers of chemical, pharmaceutical, food or petroleum products require accurate temperature measurements—especially for processes where quality or custody transfer are regulated by government agencies. Since all temperature sensors are subject to drift with time, regular calibration or verification against a reliable reference thermometer is required. Finding a reference thermometer that is accurate, repeatable and robust, however, can be challenging.

What’s wrong with my reference thermometer?

Industrial reference thermometers available on the market today, such as mercury-in-glass thermometers (or “ASTM thermometers") and portable electronic thermometers are useful, but both come with inherent problems. Although accurate and repeatable, mercury thermometers are fragile. The risk of a mercury spill poses potential hazards to the environment and to the health of personnel. Many of the United States and European Union countries have already banned their use in industrial applications. Some organizations have replaced their mercury thermometers with more durable portable electronic thermometers, only to discover that the RTD probes lack the repeatability and dependability required of a legitimate reference thermometer.

The best alternative to mercury thermometers

The Fluke “Stik" Thermometer is accurate, stable and durable, making it the best alternative to mercury thermometers and existing electronic thermometers. The thin-film RTD sensor incorporates the same characteristics of other premium reference thermometers designed by Hart Scientific, but it is more robust and less susceptible to drift. Accuracy and repeatability, however, are not sacrificed for improved durability.

Using a glass-stem mercury- or spirit-filled thermometer at different immersion depths, or at significantly different ambient temperatures from which it was calibrated, may require the application of emergent-stem corrections that can be tedious but necessary to calculate an accurate measurement. This isn’t required with the “Stik" Thermometer. The sensor of the 1551A Ex requires a minimum immersion depth of only seven centimeters (2.8 inches), with no appreciable effect on the measured temperature due to heat loss through stem conduction. Some digital thermometers can become less accurate when used outside a narrow range of ambient temperatures. This isn’t the case for the “Stik" Thermometer. Your measurement remains accurate in ambient temperatures from -10 degrees to 50 degrees celsius (14 degrees to 122 degrees fahrenheit). With a superior probe design combined with electronic functions that assist accurate measurement, the “Stik" Thermometer surpasses the capabilities of other digital thermometers and is the perfect substitute for your mercury thermometers. 1In order to minimize sensor drift, the probe should always be protected from mechanical shock.

Five reasons to replace mercury thermometers

  1. Since the “Stik" Thermometer does not contain mercury, it is not subject to government-imposed bans. Government agencies worldwide have either banned or are seeking to ban the use and transportation of industrial mercury thermometers—this seems to be a growing trend.
  2. The stainless steel probe sheath of the “Stik" Thermometer is far more robust than the glass stem of a mercury thermometer and better suited for industrial environments. And since the “Stik" thermometer does not contain mercury, the risk of an accidental mercury spill is eliminated.
  3. When considering cost of ownership, a digital thermometer is less expensive than a mercury thermometer. With a mercury thermometer, you either invest in equipment or you hire out to clean up after a mercury spill.
  4. Mercury thermometers cannot be adjusted after calibration. The actual temperature must be calculated by applying corrections to the measured temperature. This costs time and is susceptible to calculation error. A digital thermometer does the math for you—the displayed temperature accurately represents the actual measured temperature.
  5. Emergent-stem corrections may also be required if the mercury thermometer is not used under the same conditions under which it was calibrated. A digital thermometer doesn’t require that you match calibration conditions to achieve an accurate measurement. You’re only required to meet the minimum immersion requirements—which is only seven centimeters (2.8 inches) in the case of the 1551A Ex.

ZAR -1

5730A High Performance Multifunction Calibrator

sku Product SKU:  FCL-5730A

The new gold standard in electrical calibration

Since 1988, the 5700A family has set the standard for multifunction calibrator performance in calibration laboratories around the world. Now the time has come to advance this best-in-class calibrator, taking advantage of twenty-first century technology and usability.

The Fluke Calibration 5730A High Performance Multifunction Calibrator is the culmination of years of engineering development, customer research and industrial design, to bring to market the new “gold standard” in electrical multifunction calibration.

High performance for the future

Like its predecessors, the 5730A calibrates a wide range of digital multimeters, up to long-scale 8.5 digit DMMs, as well as RF voltmeters when equipped with the wideband option. But this new model features improved specifications that will help you increase test uncertainty ratios (TURs) and increase test confidence. What’s more, the improved specifications will reduce your need to guardband, giving you confidence and peace of mind in your calibrations.

  • Improved performance specifications for ac voltage, ac current and resistance
  • 6.5 inch VGA capacitive touch screen with full color graphical user interface
  • Visual Connection Management™ output terminals guide connections
  • Graphical user interface in nine languages
  • Compatible with 52120A and 5725A amplifiers
  • Full MET/CAL® compatibility with 5700A and 5720A procedures
  • Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards; 30 MHz and 50 MHz wideband output options available

ZAR -1

5430 Standard AC/DC Resistors

sku Product SKU:  FCL-5430

Six resistors in Fluke Calibration's Model 5430 series cover resistance values from 1 ohm to 10,000 ohms. Each one has an actual resistance within 10 ppm of its nominal value and holds its resistance within 2 ppm per year.

Each resistor comes with a Tinsley certificate on AC performance, traceable to NPL, including calibration uncertainty of 3 ppm. Additionally, Fluke Calibration can provide an optional DC certificate, traceable to NIST and NVLAP accredited, with uncertainty below 1 ppm.

Designed originally by a national lab, Tinsley resistors are bifilar wound to minimize reactance and are filled with oil to minimize both time- and temperature-caused instabilities. AC/DC transfer error at 90 Hz is only 0.1 ppm.

For maintaining your oil resistors, Fluke Calibration provides baths that range from 25- to 155-liter capacity with enough inside shelf space to maintain all your standard resistors. Each of these baths maintains your resistors within 1 mK in the short term (30–60 minutes) and within 5 mK for months at a time.

In our lab, we use both AC and DC bridges in addition to Super-Thermometers. We calibrate SPRTs in fixed points, and we calibrate reference resistors. We use standard resistors every day, and we understand the value of being able to rely on resistors that won’t drift. Tinsley makes the best AC/DC resistors around, and Fluke Calibration makes the best maintenance baths. Ask people who know. Then don’t compromise.

 

ZAR -1

Liquid Trap

sku Product SKU:  FCL-Liquid Trap

The 7000-102 Liquid Trap can be used with most any pneumatic test or calibration system where liquid contamination may be present in the device under test. Although the preferred procedure is to insure the device under test is free of both liquid and particulate contamination prior to calibration, the 7000-102 provides a degree of insurance to protect the calibration instrument.

The 7000-102 can be used with any calibrator, including the Model 7010 and complete line of Series 7215 Digital Pressure Controllers. It can assist with minimizing the possibility of contamination of the unique Ruska quartz sensor found in these instruments along with the control valves and solenoid valves, all of which are designed for pneumatic operation and can be damaged when exposed to liquids.  

The 7000-102 is also compatible with Druck’s line of pressure controllers including the DPI 515 and DPI 520 Digital Pressure Calibrators.

Further, the 7000-102 can be used with virtually any test or calibration system where the pressure does not exceed 3000 psi. 

A convenient drain valve allows periodic removal of accumulated liquids. Due to the pressure range, the level inside the Trap cannot be observed. Therefore it is recommended that the drain valve be opened on a frequent basis or prior to each test. A fitting is provided on the drain valve to allow connection to tubing that can run to a container for disposal.

The 7000-102 Liquid Trap is provided with a bench mount stand with two mounting holes for a sturdy installation.