The new handheld control valve tester simplifies testing with dedicated tests that perform a quick health check to provide users with good/marginal/bad results.

Control valve testing has meant using complicated testers that require extensive training, the removal of the valve, and often one-to-two hours of test time on the bench. The Fluke’s 710 mA Loop Valve Tester, allowing techs to source the 4-20 mA signal while it interrogates HART data to collect critical information about the valve’s position and status.  This provides quick checks of the control valves while they are in place. With built-in test procedures and an intuitive interface, the Fluke 710 mA Loop Valve Tester allows users to quickly and easily perform valve tests, while the valve test quick-check results provide at-a-glance diagnostics to make faster maintenance decisions.

Fluke 710 mA Loop Valve Tester has built-in HART communication function, technicians can source a 4-20 mA signal to cause the smart control valve to move, while simultaneously interpreting the valve’s HART feedback signal to determine whether the valve is moving to the expected position. In addition to positional information, the measured pressure delivered from the valve’s internal I/P (which moves the valve) can be seen with the HART communication protocol.

The Fluke 710 mA Loop Valve Tester features pre-configured valve tests for reliable and repeatable testing. The built-in routines include:

  • Manually changing the mA signal and viewing the HART position and pressure variable information.
  • Full range ramping of the mA signal from 4 to 20 to 4 mA while recording the 0-100-0 percent position, or the pressures applied that move the valve from 0-100-0 percent.
  • Stepping the mA signal on the input to the valve in steps and evaluating the valve's response to the mA input changes.
  • Speed tests to determine how fast the valve can open or close.
  • Bump and partial stroke tests help test valves over a portion of their range so they can be tested in a live process.
 
 
 

Test results are stored in the memory of the Fluke 710 mA Loop Valve Tester where it can be uploaded to the included ValveTrack™ analysis software that allows users to:

  • Upload and plot logged valve tests taken in the field.
  • Compare previous uploaded tests to recent tests.
  • View valve test history by HART Tag ID.
  • Export valve test data to CSV for additional analysis in Microsoft Excel.